STOP BUTTON (COM A+/STOP) - Safety function PL “b” according to EN13849-1
During the movement of the barrier the STOP button stops it.
If the STOP button is pressed fully open, automatic closing will be temporarily disabled
(if enabled by TCA trimmer with DL11 LED on). It will therefore be necessary to give a
new command to close the barrier.
Automatic closing will be reactivated when the barrier has closed (if it was enabled by
TCA trimmer with LED DL11 on).
HOLD-TO-RUN COMMAND OPERATION (with command maintained) IN CASE OF
FAILURE OF THE SAFETY DEVICES
If the edge is broken or engaged for more than 5 seconds, or if the photocell is faulty
or engaged for more than 60 seconds, the OPEN 1, OPEN 2, CLOSE and START
commands will only operate with maintained command.
The activation signaling of this operation is given by the DL1 led that flashes.
This operation allows opening or closing only by keeping the control buttons pressed.
The radio command and automatic closing are excluded because their operation is not
permitted by the standards.
When the safety contacts are reset, the automatic or step-by-step operation is
automatically re-enabled after 1 second, and therefore the radio control and automatic
closing are resumed.
Note 1: during this operation in the event of a coast fault (or photocells) the photocells
(or edge) still operate interrupting the maneuver in progress.
Note 2: the STOP button is not considered a safety to be bypassed in this mode, so if it
is pressed or broken, it does not allow any maneuver.
The maneuver with maintained command is exclusively an emergency maneuver
that must be carried out for short periods and with the visual safety of the
automatism movement. Faulty protections must be restored as soon as possible
for correct operation.
VISUAL AND SOUND ALARMS
BLINKER 230V 40W MAX
You can control the blinker output, through DIP 13:
DIP 13 ON =>
RAPID barrier come with the blinker already connected.
The blinker is power supplied at intermittence, with 500 ms on/off blinks during opening
and 250 ms on/off blinks during closure.
In case of safety-edge alarm, the blinker output changes intermittence turning to 2 short
blinks before going off for 2 seconds.
BUZZER
It has the task of signaling the intervention of the safety devices, the status of the alarms
and the state of memorization and cancellation of radio codes.
SIGNAL - OPEN BARRIER WARNING LIGHT - 12 Vdc 3 W MAX (SIGN. +/SIGN. -)
It has the task of signaling when the barrier is open, partially open or in any case not
completely closed. It turns off only when the barrier is completely closed.
During the opening, SIGNAL flashes slowly.
When the barrier is still or open, SIGNAL is switched on permanently.
During the closing SIGNAL flashes quickly
N.B .: Max 3 W. If you exceed the warning lights, the logic of the picture will be
compromised with possible block of operations.
TECHNICAL FEATURES
- Humidity
< 95% without condensation
- Power supply voltage
230 or 120V~ ±10%
- Frequency
50/60 Hz
- Maximum card absorbtion
28 mA
- Network microswitch
100 ms
- Barrier open warning light maximum power
3 W (equal to 1 3W bulb or to 5
LEDs connected in series through
a resistor of from 2.2 Kohm)
- Maximum power at blinker output
40 W with resistive charge
- Voltage available for photocells and accessories 500 mA 24 Vdc
- Voltage available on the radio connector
200 mA 24 Vdc
RADIO TECHNICAL FEATURES
- Reception frequency
433,92MHz
- Impedance
52 Ω
- Sensitivity
>2.24µV
- Excitation time
300ms
- De-excitation time
300ms
- Codes in store
N° 1000 total
- All the inputs must be used as clean contacts given that the power supply is generated
internally (safe voltage) in the card and it is set in a way to guarantee the use of the
double insulation and reinforced compared to parts with hazardous voltage.
- Any external circuits connected to the outputs of the control board, must be carried
out to make sure the double or reinforced insulation is used compared to parts with
hazardous voltage.
- All the inputs are run by a programmed integrated circuit which carries out an auto-test
at every start-up operation.
TROUBLE SHOOTING
After having carried out all connections, by carefully following the layout and having
positioned the gate in intermediate position, check the correct ignition of red LEDS DL6,
DL7, DL8 and DL9.
In case of no ignition of the LEDS, always with gate in intermediate position, check the
following and replace any faulty components.
DL6
OFF Stop button malfunction (if Stop is not connected, perform the jump
between COM A+ and STOP).
DL7 or DL8 OFF Faulty photocells (In case the edge is not connected, carry out jumper
between COM A+ and PHOTO 1/PHOTO 2)
DL9
OFF Faulty safety edge (In case the edge is not connected, carry out
jumper between COM A+ and EDGE)
On the board there are resettable fuses which intervene in the event of a short
circuit, interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable
connectors and insert them one at a time in order to more easily identify the cause
of the fault.
26
FRAGMA
EN
Содержание 8013406228239
Страница 75: ...1 2 3 4 5 6 7 8 9 10 4 H 3 1 5 2 9 10 8 3 7 4 6 FRAGMA 75 EL...
Страница 77: ...ELVOX 12 100 000 12 FRAGMA 77 EL...
Страница 86: ...86 FRAGMA...
Страница 87: ...87 FRAGMA...
Страница 88: ...49401526A0 01 2007 Viale Vicenza 14 36063 Marostica VI Italy www vimar com...