58
13.6.4.4 Deleting the association of the alarm with the telephone numbers where the SMS
message is to be sent
This setting enables deleting the telephone numbers to which the SMS message must be sent�
The procedure requires no response from the chronothermostat 01913�
Send the following SMS message:
<user code>.SMSAR.NUM.0
where
0
is the number zero�
Example�
If the set user code is the default 1234 and you want to delete the association of the SMS “No Mains
Power” alarm message with all the phone numbers, send the following SMS message:
1234.SMSAR.NUM.0
13.6.4.5 Customizing the Address Msg.
See paragraph 13�6�1�8 on page 41�