background image

1

2

3

1

2

3

4

5

6

7

on

VIKING

©

MODEL RC-2A

REMOTE TOUCH TONE 

RELAY CONTROLLER

VIKING

ELECTRONICS

HUDSON, WI 54016 

RELA

Y

CONT

ACTS

N.O. 

COM

N.C. 

POWER 12V DC 

1

2

3

ENTRY CODE

PROGRAMMING

SWITCHES

EARTH

GND

PWR IN/OUT

12-24V AC/DC 

LINE IN 

2

3

1

4

5

6

7

8

1

2

3

4

5

6

7

ON

ON

OFF

Switch

Position Description

1

OFF

Latch commands (10 & 19) enabled (factory
default)

1

ON

Latch commands are disabled

2

OFF

Ring delay = 15 (no rotary switches set to C,
factory default)

2

OFF

Ring delay = 2 (any rotary switch set to C)

2

ON

Ring delay = 6 (no rotary switches set to C)

2

ON

Ring delay = 1 (any rotary switch set to C)

3

OFF

Unlimited number of closures during access
time (factory default)

3

ON

One closure per correct access code during
access time (no rotary switches set to D)

4

OFF

(Not used in Legacy Programming Mode)

4

ON

(Not used in Legacy Programming Mode)

5

OFF

Legacy Programming Mode (factory default)

5

ON

Alternative Programming Mode

6

OFF

Acknowledgement tones OFF

6

ON

Acknowledgement tones ON (factory de-
fault)

7

OFF

Auto-answer OFF (factory default)

7

ON

Auto-answer ON

4

DIP switches 1-7 may be used to change the operation of the 

RC-2A

(see below).

B.  DIP Switch Settings

Note: 

DIP switches are shown in factory

default settings.

If this DIP switch is in the 

ON

position, the relay will not be able to be latched (maintained) and command

codes 10, 19 and 1# will be ignored.

Switch 1: Latch Commands

The ring delay is the number of incoming rings before the 

RC-2A

automatically answers the line. The 

RC-2A

answers on the fifteenth ring by default.  This can be changed to the first, second or sixth ring by following the
instructions above for DIP switch 

2

and rotary switch positions.

Switch 2: Ring Delay

If this DIP switch is placed in the 

ON

position, only one closure will be allowed during the access.

Switch 3: Closure Limitations

If this DIP switch is in the 

OFF

position, the 

RC-2A

is in the “Legacy Programming Mode”. In the 

ON

position,

the 

RC-2A

is in the “Alternative Programming Mode”.

Switch 5: Selecting Modes

With DIP switch 6 in the 

OFF 

position, acknowledgement tones (beeps for relay confirmation, etc.) are turned

off.  With DIP switch 6 in the 

ON

position, acknowledgement tones are on.

Switch 6: Relay Acknowledgement Tones

With DIP switch 7 in the 

OFF

position, the automatic phone line answering feature is turned off.  With DIP

switch 7 in the 

ON

position, the automatic phone line answering feature is turned on. See DIP switch 2 and

rotary switch positions for ring delay (total number of incoming rings before the unit automatically answers the
line).

Switch 7: Automatic Answer

This DIP switch is only used in the “Alternative Programming Mode” and has no function in the “Legacy Mode”.

Switch 4: Relay Activation Times

Содержание RC-2A

Страница 1: ...y open or normally closed relay Selectable relay closure times Selectable ring delay 1 2 6 or 15 Universal 12 24V AC DC power input Easy installation with screw terminals and dip switch programming Automatic disconnect or return to secure mode after 60 seconds Power multiple units from one adapter One year warranty Remote Control of High security building entry Heating cooling equipment Pumps and ...

Страница 2: ...hich RC 2A mode works best for your application The RC 2A has two operational modes built in called the Legacy and Alternative modes The Legacy mode is the standard mode of operation that has existed in all previous versions of the RC 2A The Alternative mode is a second mode of operation that increases the RC 2A s flexibility in some applications The operational mode you should use depends on the ...

Страница 3: ...n program the digits dialed to activate the relay 2 Disadvantages a There are no latch unlatch relay commands b There is no Touch Tone hang up command c Fewer ring delay selections for remote access 2 or 15 rings only B Legacy Mode C Alternative Mode Legacy Programming Mode Important The RC 2A ships by default in the Legacy Programming mode DIP switch 5 OFF Optional programming is also available s...

Страница 4: ...sition the relay will not be able to be latched maintained and command codes 10 19 and 1 will be ignored Switch 1 Latch Commands The ring delay is the number of incoming rings before the RC 2A automatically answers the line The RC 2A answers on the fifteenth ring by default This can be changed to the first second or sixth ring by following the instructions above for DIP switch 2 and rotary switch ...

Страница 5: ...nd operation are changed dra matically Please use the following programming sections only when programming in the Alternative Programming Mode All Legacy Programming and Operation become un usable and you may ONLY program and operate the RC 2A using the information provided in the following sections Rotary Switch Touch Tone F Ignore C B Q 0 9 0 9 To program a single digit relay activation code set...

Страница 6: ... 24V AC DC LINE IN 2 3 1 4 5 6 7 8 1 2 3 4 5 6 7 ON ON OFF Switch 1 Switch 2 Switch 3 Switch 4 Relay Activation Time OFF OFF OFF OFF 1 2 second OFF OFF OFF ON 1 second OFF OFF ON OFF 2 seconds OFF OFF ON ON 3 seconds OFF ON OFF OFF 4 seconds OFF ON OFF ON 5 seconds OFF ON ON OFF 6 seconds OFF ON ON ON 7 seconds ON OFF OFF OFF 8 seconds ON OFF OFF ON 9 seconds ON OFF ON OFF 10 seconds ON OFF ON ON ...

Страница 7: ... two digit relay activation code see page 5 C Relay Activation Codes A single or double beep ac knowledgement tone should be heard Step 4 If a security code has been set no code switches set to D enter 8 or 18 before hanging up to place the RC 2A back into secure mode Alternatively the unit will automatically return to the secure mode if no Touch Tones are detected for 60 seconds 2 Accessing the R...

Страница 8: ...TOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF WARRANTIES EXCLUSION OF CONSEQUENTIAL DAMAGES AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH DOD 160 ZF302020 Rev B Due to the dynamic nature of t...

Отзывы: