background image

These activation codes are pre-programmed and cannot be changed except when using the  

Alternative Pro-

gramming

mode.

C.  Relay Activation Codes

In the “Alternative Programming Mode” (DIP switch 5 

ON

), access to the 

RC-2A

is im-

mediate and it becomes possible to program a one, two or three digit relay activation
code.  No security access code is programmable or required to gain access.

A.  Security

The entry code switches set the relay activation code.  In addition to the rotary switch
positions shown in the chart, this code can also make use of positions D and E, as long
as the user is aware that 

D

and 

E

can only be entered using a special 4x4 keypad.  

Note:

For more information on using the 

RC-2A

with a special 4x4 keypad, retrieve 

DOD# 855

.

B.  Entry Code Switches

5

Touch Tone/s

Enter

To energize relay (two beeps)

10

To de-energize relay (one beep)

19

To energize relay momentarily (.5 seconds) (one beep)

13

To energize relay while 

4

is pressed and for 1 second after (one beep)

14

To energize relay as long as 

5

is pressed (.5 seconds minimum) (one beep)

15

To energize relay while 

6

is pressed, and 5 seconds after (one beep)

16

To interrogate the relay status (two beeps - energized, one beep - de-energized)

1#

To release the phone line / return to secure mode (three beeps)

18 or 8

Alternative Programming Mode

Important: 

In the “Alternative Programming Mode” (DIP switch 5 

ON

), programming and operation are changed dra-

matically.  Please use the following programming sections only when programming in the “Alternative Programming
Mode”.  All “Legacy” Programming and Operation become un-usable and you may 

ONLY

program and operate the

RC-2A

using the information provided in the following sections.

Rotary
Switch

Touch

Tone

F

Ignore

C

#

B

Q

0...9

0...9

To program a single digit relay activation code, set any two of the three
code switches to 

F

.  

Example:  FF3

(shown right).

1. Single Digit Relay Activation Code

To program a two-digit relay activation code, set any one of the code
switches to 

F

.  The other two switch settings comprise the relay activation

code.  

Example:  F47

(shown right).

2. Two-Digit Relay Activation Code

To program the relay activation code to be 

Q

or 

#

, set all three code switches

to F (shown right).  In this case, either a 

Q

or 

will activate the relay.

3. Special Character Relay Activation Code

The ring delay is the number of incoming rings before the 

RC-2A

automati-

cally answers the line. To program the ring delay to 2 instead of the normal
15, set at least one of the code switches to B or C (shown right).  

Example:

FFB =

Q

” as the activation code and 

2

as the ring delay. 

4. Ring Delay

0 1 23

45

678

9A

BC

D

EF

0 1 23

45

678

9A

BC

D

EF

0 1 23

45

678

9A

BC

D

EF

0 1 23

45

678

9A

BC

D

EF

0 1 23

45

678

9A

BC

D

EF

0 1 23

45

678

9A

BC

D

EF

0 1 23

45

678

9A

BC

D

EF

0 1 23

45

678

9A

BC

D

EF

0 1 23

45

678

9A

BC

D

EF

0 1 23

45

678

9A

BC

D

EF

0 1 23

45

678

9A

BC

D

EF

0 1 23

45

678

9A

BC

D

EF

Содержание RC-2A

Страница 1: ...y open or normally closed relay Selectable relay closure times Selectable ring delay 1 2 6 or 15 Universal 12 24V AC DC power input Easy installation with screw terminals and dip switch programming Automatic disconnect or return to secure mode after 60 seconds Power multiple units from one adapter One year warranty Remote Control of High security building entry Heating cooling equipment Pumps and ...

Страница 2: ...hich RC 2A mode works best for your application The RC 2A has two operational modes built in called the Legacy and Alternative modes The Legacy mode is the standard mode of operation that has existed in all previous versions of the RC 2A The Alternative mode is a second mode of operation that increases the RC 2A s flexibility in some applications The operational mode you should use depends on the ...

Страница 3: ...n program the digits dialed to activate the relay 2 Disadvantages a There are no latch unlatch relay commands b There is no Touch Tone hang up command c Fewer ring delay selections for remote access 2 or 15 rings only B Legacy Mode C Alternative Mode Legacy Programming Mode Important The RC 2A ships by default in the Legacy Programming mode DIP switch 5 OFF Optional programming is also available s...

Страница 4: ...sition the relay will not be able to be latched maintained and command codes 10 19 and 1 will be ignored Switch 1 Latch Commands The ring delay is the number of incoming rings before the RC 2A automatically answers the line The RC 2A answers on the fifteenth ring by default This can be changed to the first second or sixth ring by following the instructions above for DIP switch 2 and rotary switch ...

Страница 5: ...nd operation are changed dra matically Please use the following programming sections only when programming in the Alternative Programming Mode All Legacy Programming and Operation become un usable and you may ONLY program and operate the RC 2A using the information provided in the following sections Rotary Switch Touch Tone F Ignore C B Q 0 9 0 9 To program a single digit relay activation code set...

Страница 6: ... 24V AC DC LINE IN 2 3 1 4 5 6 7 8 1 2 3 4 5 6 7 ON ON OFF Switch 1 Switch 2 Switch 3 Switch 4 Relay Activation Time OFF OFF OFF OFF 1 2 second OFF OFF OFF ON 1 second OFF OFF ON OFF 2 seconds OFF OFF ON ON 3 seconds OFF ON OFF OFF 4 seconds OFF ON OFF ON 5 seconds OFF ON ON OFF 6 seconds OFF ON ON ON 7 seconds ON OFF OFF OFF 8 seconds ON OFF OFF ON 9 seconds ON OFF ON OFF 10 seconds ON OFF ON ON ...

Страница 7: ... two digit relay activation code see page 5 C Relay Activation Codes A single or double beep ac knowledgement tone should be heard Step 4 If a security code has been set no code switches set to D enter 8 or 18 before hanging up to place the RC 2A back into secure mode Alternatively the unit will automatically return to the secure mode if no Touch Tones are detected for 60 seconds 2 Accessing the R...

Страница 8: ...TOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF WARRANTIES EXCLUSION OF CONSEQUENTIAL DAMAGES AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH DOD 160 ZF302020 Rev B Due to the dynamic nature of t...

Отзывы: