background image

Operation

If the 

RC-2A

is programmed to answer a ringing line (DIP switch 7 ON), it will answer after the selected ring delay.

A single acknowledgement tone will be heard, signaling the user that the 

RC-2A

has answered the line.  If a se-

curity access code has been programmed (no code switches set to 

D

), a touch-tone "

Q

" plus the security access

code may be entered at this time and a second acknowledgement tone will be heard.  After this acknowledgement
tone, the built in 2 digit relay commands can be dialed (see page 5, 

C. Relay Activation Codes

). If "

Q

" plus an

incorrect security access code is entered, the 

RC-2A

will immediately disconnect (hang-up).  To prevent unau-

thorized use, if a user dials "

Q

" plus an incorrect security access code on 5 consecutive incoming calls, the unit

will disconnect and not answer the line for 60 minutes.  

If the 

RC-2A

is not programmed to answer the line (DIP switch 7 OFF), it can passively monitor a communication

path for the proper access and/or activation code.

The 

RC-2A

provides a relay activation (opening or closing a relay contact) remotely via DTMF Touch Tone input

over a standard analog C.O. line or PABX/KSU station.  When the correct relay activation code is entered, the

RC-2A

activates its relay contacts on the terminal strip followed by an acknowledgement tone. 

A.  Legacy Mode

6

1

2

3

1

2

3

4

5

6

7

on

VIKING

©

MODEL RC-2A

REMOTE TOUCH TONE 

RELAY CONTROLLER

VIKING

ELECTRONICS

HUDSON, WI 54016 

RELA

Y

CONT

ACTS

N.O. 

COM

N.C. 

POWER 12V DC 

1

2

3

ENTRY CODE

PROGRAMMING

SWITCHES

EARTH

GND

PWR IN/OUT

12-24V AC/DC 

LINE IN 

2

3

1

4

5

6

7

8

1

2

3

4

5

6

7

ON

ON

OFF

Switch 1

Switch 2

Switch 3

Switch 4

Relay Activation

Time

OFF

OFF

OFF

OFF

1/2 second

OFF

OFF

OFF

ON

1 second

OFF

OFF

ON

OFF

2 seconds

OFF

OFF

ON

ON

3 seconds

OFF

ON

OFF

OFF

4 seconds

OFF

ON

OFF

ON

5 seconds

OFF

ON

ON

OFF

6 seconds

OFF

ON

ON

ON

7 seconds

ON

OFF

OFF

OFF

8 seconds

ON

OFF

OFF

ON

9 seconds

ON

OFF

ON

OFF

10 seconds

ON

OFF

ON

ON

30 seconds

ON

ON

OFF

OFF

45 seconds

ON

ON

OFF

ON

1 minute

ON

ON

ON

OFF

5 minutes

ON

ON

ON

ON

10 minutes

Note: 

DIP switches are shown in factory

default settings.

DIP switches 1-4 provide 16 different relay activation times according to the following table:

C.  DIP Switch Settings

Switch

Position

Description

5

OFF

Legacy Programming Mode (factory default)

5

ON

Alternative Programming Mode

6

OFF

Acknowledgement tones OFF

6

ON

Acknowledgement tones ON (factory default)

7

OFF

Auto-answer OFF (factory default)

7

ON

Auto-answer ON

1. Accessing the RC-2A Remotely

Step 1.

Set DIP switch 7 to ON and call the 

RC-2A

using a Touch Tone phone.

Step 2.

When the 

RC-2A

answers, a single beep (acknowledgement tone) will be heard.

Step 3.

If the security access code has been disabled (one or more code switches set to 

D

), go to step 4.

If a security access code has been set (no code switches set to 

D

), enter "

Q

" followed by your 3

digit security access code (see page 3, 

A. Security Access Code

).

Step 4.

Enter a two digit relay activation code (see page 5, 

C. Relay Activation Codes

). A single or dou-

ble beep (acknowledgement tone) should be heard.

Step 5.

Enter "

8

" or "

18

" before hanging up to force the 

RC-2A

to release the line.  Alternatively, the unit

will disconnect if no Touch Tones are detected for 60 seconds.

Step 6.

Set DIP switch 7 to the desired position.

Содержание RC-2A

Страница 1: ...y open or normally closed relay Selectable relay closure times Selectable ring delay 1 2 6 or 15 Universal 12 24V AC DC power input Easy installation with screw terminals and dip switch programming Automatic disconnect or return to secure mode after 60 seconds Power multiple units from one adapter One year warranty Remote Control of High security building entry Heating cooling equipment Pumps and ...

Страница 2: ...hich RC 2A mode works best for your application The RC 2A has two operational modes built in called the Legacy and Alternative modes The Legacy mode is the standard mode of operation that has existed in all previous versions of the RC 2A The Alternative mode is a second mode of operation that increases the RC 2A s flexibility in some applications The operational mode you should use depends on the ...

Страница 3: ...n program the digits dialed to activate the relay 2 Disadvantages a There are no latch unlatch relay commands b There is no Touch Tone hang up command c Fewer ring delay selections for remote access 2 or 15 rings only B Legacy Mode C Alternative Mode Legacy Programming Mode Important The RC 2A ships by default in the Legacy Programming mode DIP switch 5 OFF Optional programming is also available s...

Страница 4: ...sition the relay will not be able to be latched maintained and command codes 10 19 and 1 will be ignored Switch 1 Latch Commands The ring delay is the number of incoming rings before the RC 2A automatically answers the line The RC 2A answers on the fifteenth ring by default This can be changed to the first second or sixth ring by following the instructions above for DIP switch 2 and rotary switch ...

Страница 5: ...nd operation are changed dra matically Please use the following programming sections only when programming in the Alternative Programming Mode All Legacy Programming and Operation become un usable and you may ONLY program and operate the RC 2A using the information provided in the following sections Rotary Switch Touch Tone F Ignore C B Q 0 9 0 9 To program a single digit relay activation code set...

Страница 6: ... 24V AC DC LINE IN 2 3 1 4 5 6 7 8 1 2 3 4 5 6 7 ON ON OFF Switch 1 Switch 2 Switch 3 Switch 4 Relay Activation Time OFF OFF OFF OFF 1 2 second OFF OFF OFF ON 1 second OFF OFF ON OFF 2 seconds OFF OFF ON ON 3 seconds OFF ON OFF OFF 4 seconds OFF ON OFF ON 5 seconds OFF ON ON OFF 6 seconds OFF ON ON ON 7 seconds ON OFF OFF OFF 8 seconds ON OFF OFF ON 9 seconds ON OFF ON OFF 10 seconds ON OFF ON ON ...

Страница 7: ... two digit relay activation code see page 5 C Relay Activation Codes A single or double beep ac knowledgement tone should be heard Step 4 If a security code has been set no code switches set to D enter 8 or 18 before hanging up to place the RC 2A back into secure mode Alternatively the unit will automatically return to the secure mode if no Touch Tones are detected for 60 seconds 2 Accessing the R...

Страница 8: ...TOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF WARRANTIES EXCLUSION OF CONSEQUENTIAL DAMAGES AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH DOD 160 ZF302020 Rev B Due to the dynamic nature of t...