Viking K-1775-IP Series Скачать руководство пользователя страница 18

18

If enabled and a busy is detected, the 

K-1775-IP

phone will dial the “Roll Over” speed dial number. 

Notes:

This feature is enabled in the factory default setting. If the busy signal is interrupted with a promotional message,

contact your central office to have it removed.

38.  Dial Next Number on Busy 

39. Live Dialing Format

40. REX Input

The Live Dialing Format can be set to In-Band DTMF (Touch Tones) or RFC 2833 (Out of band DTMF Touch Tones).
Live dialing refers to the numbers dialed after and outbound call has been answered by the distant party. This would
typically be the numbers dialed to steer through automated attendants, voice mail, etc. If your VoIP phone system does
not automatically convert out of band DTMF to In-Band after the call is answered, set Live Dialing Format to “Inband
DTMF”

The 

K-1775-IP

has one Reguest for Exit (REX) trigger input. The REX switch must have a momentary, normally open-

contact. When the 

K-1775-IP

detects a contact closure on the REX trigger input and relay 2 mode is not set to Door

Strike, reay 1 will be energized for the preprogrammed relay activation time. If relay 2 is set to door strike then relay 2
will activate from the REX switch. This is useful in two door vestibule applications where relay 1 is used to unlock the
outside door and relay 2 to unlock the inside door.

Operation

A.  “CALL” Button

B.  Remote Access Operation Commands

The following commands can be entered after answering an inbound call from the entry phone. The commands can
also be entered on an outbound call to the entry phone. After the entry phone auto answers the call, two beeps will be
heard. If the access code has been disabled, you can now enter the Remote Access Operation Commands below. If an
Access code has been programmed, enter the Access code digits. With the correct code entered, two beeps will be
heard and you can now enter the Remote Access Operation Commands below.

With the call button Auto Dial Delay set to 0/Disable (factory default), when the “

CALL

” button is pressed, the 

K-1775-

IP

phone immediately dials the pre-programmed telephone number stored in the Phone Number Database Index location

0. With the call button Auto Dial Delay set from 1 - 6, when the “

CALL

” button is pressed you will hear 1 - 6 seconds of

dial tone, allowing you time to enter the 1-3 digit Speed Dial number. The unit will then dial the Phone Number Database
Index location 0-250 associated with the preprogrammed 1-3 digit Speed Dial Number (0-999). The Call Status LED
momentarily flashes during dialing. In the event the line is busy or there is a ring-no-answer, the unit can be programmed
to call a second roll over number.

When the call is answered, the phones are factory programmed to automatically light the “Call Status” LED to show    

that handsfree communication to personnel is established. Once the “Call Status” LED is on, relay activation commands
can be entered or the # key can be used to force the phone to hang-up.

After communication is established, enter the 1 or 2 digit relay activation command (factory set to “

QQ

for Relay 1 and

Q

2” for Relay 2

) to momentarily activate the entry phone (door strike) relay. If the (door strike) relay is activated, two

beeps    will be heard confirming the relay has been activated. If you require the relay to remain on continuously (ie: a
truck delivery), enter Touch Tones “

11 or 21

” to continuously activate that relay. A double beep will indicate the (door

strike) relay is latched on. When the visitor calls in again (ie: they are finished unloading the truck), enter Touch Tones

10 or 20

” to deactivate that relay. A single beep will indicate the (door strike) relay is latched off.

Содержание K-1775-IP Series

Страница 1: ...allation and Specifications Operating Temperature 40 C to 60 C 40 F to 140 F Humidity Standard Products 5 to 95 non condensing Humidity EWP Products Up to 100 Audio Codecs G711u G711a G722 Network Com...

Страница 2: ...vice Provider 3COM VCX X 3CX X Aastra X Asterisk X Atcom X Avaya IP Office X BlueBox X Brekeke X Callcentric X Cisco Unified Communications Manager CUCM X X Cisco Unified Communications Manager Expres...

Страница 3: ...r Media Access Control A MAC address also called a hardware address or physical address is a unique address assigned to a device at the factory It resides in the device s memory and is used by routers...

Страница 4: ...nches Push Button Switch Push to initiate call push again to disconnect Solid 316 stainless steel internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots to prevent punctures fr...

Страница 5: ...PR S 8 TU V 9 WX Y 0 OP ER Call VIKING 1 2 ABC 3 DEF 4 GHI 5 JKL 6 MNO 7 PRS 8 TUV 9 WX Y 0 OPER Marine grade 316 stainless steel faceplate and push button switch sealed per IP67 For more information...

Страница 6: ...Using CAT5E or CAT6 for Analog Video see Caution below Video GND Green Video Out W G Up to 150 ft 3 Wire Gel Filled Butt Connectors included 3M Scotchlok UR2 CAT5E or CAT6 Cable see Caution below Phon...

Страница 7: ...the network For more information go to www axis com D Adjusting the Camera The camera can be tilted and rotated to your desired po sition A portable service test monitor can be used to de termine the...

Страница 8: ...etic Lock 120V AC Connect to Doorstrike Mag Lock Gate Controller etc Door near Entry Phone 3 N O COM Relay 3 Output Contacts 5A 30VDC 250VAC max 2 Gel Filled Butt Connectors included Power typically n...

Страница 9: ...indicating a SIP registration failure failure to receive an echo reply from pinged gateway or Ethernet connection failure You can manually disable the beeps by pressing and holding the Call button for...

Страница 10: ...later then release the button The Call LED will remain off for the first 3 seconds flash slowly for 3 seconds 2 beeps fast flash for 6 seconds 4 beeps then light steady indicating when to release butt...

Страница 11: ...m Mode factory set to Door Strike 16 23 Relay 1 or 2 Command 1 or 2 digits factory set to QQ and Q2 Relay Mode must be set to Door Strike 16 24 Relay 1 or 2 Time 0 5 99 sec factory set to 5 sec 16 25...

Страница 12: ...it number visitors enter on the K 1775 IP s keypad for the unit to call the tenant 3 seconds after the 1 to 3 digit number is entered the unit will then dial the Primary Phone Number associated with t...

Страница 13: ...Proximity Card Facility Code Day of week Time of Day and Tenant Name The Event Log button is used to open the Event Log screen The Event Log screen shows you the time and date of each event the event...

Страница 14: ...settings 10 Factory Default The security code allows the user installer to program the K 1775 IP phone The factory set security code is 845464 V I K I N G It is recommended that the factory set secur...

Страница 15: ...th Log Errors selected the K 1775 IP will not only log all valid Keyless Entry Code and Proximity Card entry s but also log any errors or incorrect codes or non valid card reads Keyless Entry Code and...

Страница 16: ...rm Mode When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered and reg istered to the SIP server In the event the unit loses power and or SIP registration...

Страница 17: ...automatically increase The ANC mode is useful in applications where the background noise level can change drastically such as a gas car running vs a diesel truck 32 Mic Volume Automatic Noise Cancelli...

Страница 18: ...elow If an Access code has been programmed enter the Access code digits With the correct code entered two beeps will be heard and you can now enter the Remote Access Operation Commands below With the...

Страница 19: ...ovide keyless entry The K 1775 IP can be programmed with a combination of up to 1000 keyless entry codes or one time use keyless entry codes The keyless entry codes can be programmed to be from 1 to 6...

Страница 20: ...communications Note The VE 3x5 is not compatible with the VE GNP pedestals The VE PNL s are VE Series backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to m...

Страница 21: ...Proximity Card Readers The PRX C and PRX C ISO are non contact security cards that can be presented to the front of a K 1770 75 IP proximity card reader to allow entrance into a secured area The PRX C...

Страница 22: ...YEAR LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials under normal use and service for a period of two years from the date of purchase from any au...