Viking K-1775-IP Series Скачать руководство пользователя страница 14

14

5. Phone Name

6. Mute Alarm Until Next Failure

7. Phone Firmware

8. IP Firmware

9 Import/Export

Up to a 32 digit phone name can be assigned to the 

K-1775-IP

being programmed. Often times the building name and

entrance location near the unit are used for the name.

A network failure alarm will be indicated by flashing the “Call” LED on the front panel and the speaker outputting 3 beeps
every minute. A network failure indicates the unit is not registered to the SIP server or there is a communication failure
with the gateway. The three beeps can be muted by clicking on the “Mute Alarm Until Next Failure”.   

If new 

K-1775-IP

firmware is available, after opening the programming software a pop window will come up asking you

if you would like to update firmware. An alternative method of updating can be done by clicking the phone firmware “Up-
date” button. You can then browse to the folder that contains the HEX file for updating the unit’s firmware. This method
is typically only used when Viking Technical Support has sent you updated firmware.

If new 

K-1775-IP

firmware is available, after opening the programming software a pop window will come up asking you

if you would like to update firmware. An alternative method of updating can be done by clicking the IP firmware “Update”
button. You can then browse to the folder that contains the PIP file for updating the unit’s IP firmware. This method is
typically only used when Viking Technical Support has sent you updated IP firmware

The Import/Export feature is useful for backing up all the 

K-1775-IP’s

programming or for importing programming when

installing multiple units with a majority of the same programming.

Clicking on the “Factory Default ” button in programming will reset all of the Programming Features back to their factory
default settings. 

Note: 

This    command will not change or reset your IP settings.

10. Factory Default 

The security code allows the user/installer to program the 

K-1775-IP

phone.  The factory set security code is 845464

(V-I-K-I-N-G).  It is recommended that the factory set security code be changed.

Note:

The security code must be 6 digits and cannot include a 

Q

or a 

#

.

12.  Security Code 

11. Diagnostics

The Diagnostics section in the 

K-1700-IP

PC Programming can be used to test the functionality of the MIC, Speaker

and Relays.

The Access Code is used for remotely operating the relays (Doorstrike, Mag-Lock, etc) by calling into the unit. This
code provides basic security and only allows operation of the relays and not the ability to change any of the programming
parameters. Once entered, any of the “Remote Access Operation Commands” can be used. The code can be 1 to 6
digits in length and cannot contain a “

Q

”,  “#” or match the numbers used for the security code.  Simply call the 

K-1775-

IP

phone, the unit will automatically answer the line and output two beeps. You then enter the programmed 1 to 6 digit

access code, 2 beeps should be heard. You can now enter any “Remote Access Operation Commands” (see page 12).

13.  Access Code 

The Auto Answer/Loud Ring feature can be set to one of four modes.

0 = Disabled

:  In the “Disabled” mode the phone will not automatically answer an incoming call. 

1 = Auto Answer

(factory setting):  In the “Auto Answer” mode the phone will automatically answer an incoming call on

the first ring. 

2 = Loud Ring

:  In the “Loud Ring” mode the phone will not automatically answer an incoming call but will output a loud

ring signal out of the speaker in a 2 seconds on, 4 seconds off ring pattern. The call can then be answered by pressing
the button.

3 = Loud Ring with AGC

:  In the “Loud Ring with AGC” mode the phone will not automatically answer an incoming call

but will output a loud ring signal out of the speaker in a 2 seconds on, 4 seconds off ring pattern. The phone will auto-
matically increase or decrease the ring volume based on background ambient noise. The call can then be answered by
pressing the button.

14. Auto Answer / Loud Ring 

Содержание K-1775-IP Series

Страница 1: ...allation and Specifications Operating Temperature 40 C to 60 C 40 F to 140 F Humidity Standard Products 5 to 95 non condensing Humidity EWP Products Up to 100 Audio Codecs G711u G711a G722 Network Com...

Страница 2: ...vice Provider 3COM VCX X 3CX X Aastra X Asterisk X Atcom X Avaya IP Office X BlueBox X Brekeke X Callcentric X Cisco Unified Communications Manager CUCM X X Cisco Unified Communications Manager Expres...

Страница 3: ...r Media Access Control A MAC address also called a hardware address or physical address is a unique address assigned to a device at the factory It resides in the device s memory and is used by routers...

Страница 4: ...nches Push Button Switch Push to initiate call push again to disconnect Solid 316 stainless steel internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots to prevent punctures fr...

Страница 5: ...PR S 8 TU V 9 WX Y 0 OP ER Call VIKING 1 2 ABC 3 DEF 4 GHI 5 JKL 6 MNO 7 PRS 8 TUV 9 WX Y 0 OPER Marine grade 316 stainless steel faceplate and push button switch sealed per IP67 For more information...

Страница 6: ...Using CAT5E or CAT6 for Analog Video see Caution below Video GND Green Video Out W G Up to 150 ft 3 Wire Gel Filled Butt Connectors included 3M Scotchlok UR2 CAT5E or CAT6 Cable see Caution below Phon...

Страница 7: ...the network For more information go to www axis com D Adjusting the Camera The camera can be tilted and rotated to your desired po sition A portable service test monitor can be used to de termine the...

Страница 8: ...etic Lock 120V AC Connect to Doorstrike Mag Lock Gate Controller etc Door near Entry Phone 3 N O COM Relay 3 Output Contacts 5A 30VDC 250VAC max 2 Gel Filled Butt Connectors included Power typically n...

Страница 9: ...indicating a SIP registration failure failure to receive an echo reply from pinged gateway or Ethernet connection failure You can manually disable the beeps by pressing and holding the Call button for...

Страница 10: ...later then release the button The Call LED will remain off for the first 3 seconds flash slowly for 3 seconds 2 beeps fast flash for 6 seconds 4 beeps then light steady indicating when to release butt...

Страница 11: ...m Mode factory set to Door Strike 16 23 Relay 1 or 2 Command 1 or 2 digits factory set to QQ and Q2 Relay Mode must be set to Door Strike 16 24 Relay 1 or 2 Time 0 5 99 sec factory set to 5 sec 16 25...

Страница 12: ...it number visitors enter on the K 1775 IP s keypad for the unit to call the tenant 3 seconds after the 1 to 3 digit number is entered the unit will then dial the Primary Phone Number associated with t...

Страница 13: ...Proximity Card Facility Code Day of week Time of Day and Tenant Name The Event Log button is used to open the Event Log screen The Event Log screen shows you the time and date of each event the event...

Страница 14: ...settings 10 Factory Default The security code allows the user installer to program the K 1775 IP phone The factory set security code is 845464 V I K I N G It is recommended that the factory set secur...

Страница 15: ...th Log Errors selected the K 1775 IP will not only log all valid Keyless Entry Code and Proximity Card entry s but also log any errors or incorrect codes or non valid card reads Keyless Entry Code and...

Страница 16: ...rm Mode When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered and reg istered to the SIP server In the event the unit loses power and or SIP registration...

Страница 17: ...automatically increase The ANC mode is useful in applications where the background noise level can change drastically such as a gas car running vs a diesel truck 32 Mic Volume Automatic Noise Cancelli...

Страница 18: ...elow If an Access code has been programmed enter the Access code digits With the correct code entered two beeps will be heard and you can now enter the Remote Access Operation Commands below With the...

Страница 19: ...ovide keyless entry The K 1775 IP can be programmed with a combination of up to 1000 keyless entry codes or one time use keyless entry codes The keyless entry codes can be programmed to be from 1 to 6...

Страница 20: ...communications Note The VE 3x5 is not compatible with the VE GNP pedestals The VE PNL s are VE Series backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to m...

Страница 21: ...Proximity Card Readers The PRX C and PRX C ISO are non contact security cards that can be presented to the front of a K 1770 75 IP proximity card reader to allow entrance into a secured area The PRX C...

Страница 22: ...YEAR LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials under normal use and service for a period of two years from the date of purchase from any au...