15. Ring Cadence

16. Loud Ring Volume

17. Phone Mode

18. Call Button Delay

19. Call Button Auto Dial

The Phone Mode can be programmed to one of two settings: Auto Dialer or Manual Dial Phone. When set to Auto Dialer
the 

K-1775-IP

will auto dial any preprogrammed phone numbers stored in the Phone Number Database when the cor-

responding Speed Dial Number (example: apartment number) is entered on the units keypad. When set to Manual Dial
Phone the units auto dialing features are disabled and the unit functions like a standard VoIP speaker phone. Pressing
the call button will take the phone off hook allowing you to manually dial the phone number on the keypad.    

The Call Button Delay is the length of time from when the Call button is pressed and when the unit starts dialing the
Primary number programmed in Speed Dial location 0. The time is programmable from 0 to 6 seconds. Adding Call
Button Delay time is useful to allow visitors time after they have pressed the Call button to then enter the tenants
apartment number (Speed Dial Number) or their Keyless Entry Code. 

The Call Button Auto Dial feature allows visitors that do not know the tenants apartment number (Speed Dial Number),
a way of simply pressing the Call button with no additional numbers entered. After the Call Button Delay the unit will
automatically dial the Primary Phone Number stored in Speed Dial location 0. This could route the call to the building
manager, care taker, receptionist, etc.

Keyless Entry Code and Proximity Card logging can be set to Log Errors. With Log Errors selected, the 

K-1775-IP

will

not only log all valid Keyless Entry Code and Proximity Card entry’s but also log any errors or incorrect codes or non-
valid card reads.

Keyless Entry Code and Proximity Card logging can also be set to Live Logging. With Live logging selected and the 

K-

1775-IP

programming software open and connected to a unit, each Keyless Entry Code entered or Proximity Card read

will immediately open the Event Log screen and display the latest entry.

When using date and time logged events or setting the access date and times of keyless codes or proximity cards in
the Entry Code Database you must program the unit to your time zone. Example: You are installing the 

K-1775-IP

in

Central standard time zone. Select (UTC - 06:00) C, which is 6 hours behind Coordinated Universal Time (UTC).

The Loud Ring Volume can be set from 0 – 9. 1 = the lowest volume, 9 = the highest volume and 0 = disabled.  

When “Auto Answer/Ring” on the 

K-1775-IP

is set to “Loud Ring” or “Loud Ring with AGC” the Loud Ring cadence can

be programmed to one of 4 different cadence. Normal Ring (single ring, 2 sec on 4 sec off), Double Ring (double ring,
1 sec on .5 sec off 1 sec on 3.5 sec off), Short-Short-Long (triple ring, .5 sec on .5 sec off .5 sec on .5 sec off 1 sec on
3 sec off), Short-Long-Short (triple ring, .5 sec on .5 sec off 1 sec on .5 sec off .5 sec on 3 sec off).

20. Select Time Zone

The Daylight Saving Time programming can be enabled or disabled and can be programmed to start on any Sunday in
March and stopped on any Sunday in November. Currently, daylight saving time starts on the second Sunday in March
and ends on the first Sunday in November, with the time changes taking place at 2:00 a.m. local time.

21. Daylight Savings

22. Keyless/Card Logging

Содержание K-1775-IP Series

Страница 1: ...allation and Specifications Operating Temperature 40 C to 60 C 40 F to 140 F Humidity Standard Products 5 to 95 non condensing Humidity EWP Products Up to 100 Audio Codecs G711u G711a G722 Network Com...

Страница 2: ...vice Provider 3COM VCX X 3CX X Aastra X Asterisk X Atcom X Avaya IP Office X BlueBox X Brekeke X Callcentric X Cisco Unified Communications Manager CUCM X X Cisco Unified Communications Manager Expres...

Страница 3: ...r Media Access Control A MAC address also called a hardware address or physical address is a unique address assigned to a device at the factory It resides in the device s memory and is used by routers...

Страница 4: ...nches Push Button Switch Push to initiate call push again to disconnect Solid 316 stainless steel internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots to prevent punctures fr...

Страница 5: ...PR S 8 TU V 9 WX Y 0 OP ER Call VIKING 1 2 ABC 3 DEF 4 GHI 5 JKL 6 MNO 7 PRS 8 TUV 9 WX Y 0 OPER Marine grade 316 stainless steel faceplate and push button switch sealed per IP67 For more information...

Страница 6: ...Using CAT5E or CAT6 for Analog Video see Caution below Video GND Green Video Out W G Up to 150 ft 3 Wire Gel Filled Butt Connectors included 3M Scotchlok UR2 CAT5E or CAT6 Cable see Caution below Phon...

Страница 7: ...the network For more information go to www axis com D Adjusting the Camera The camera can be tilted and rotated to your desired po sition A portable service test monitor can be used to de termine the...

Страница 8: ...etic Lock 120V AC Connect to Doorstrike Mag Lock Gate Controller etc Door near Entry Phone 3 N O COM Relay 3 Output Contacts 5A 30VDC 250VAC max 2 Gel Filled Butt Connectors included Power typically n...

Страница 9: ...indicating a SIP registration failure failure to receive an echo reply from pinged gateway or Ethernet connection failure You can manually disable the beeps by pressing and holding the Call button for...

Страница 10: ...later then release the button The Call LED will remain off for the first 3 seconds flash slowly for 3 seconds 2 beeps fast flash for 6 seconds 4 beeps then light steady indicating when to release butt...

Страница 11: ...m Mode factory set to Door Strike 16 23 Relay 1 or 2 Command 1 or 2 digits factory set to QQ and Q2 Relay Mode must be set to Door Strike 16 24 Relay 1 or 2 Time 0 5 99 sec factory set to 5 sec 16 25...

Страница 12: ...it number visitors enter on the K 1775 IP s keypad for the unit to call the tenant 3 seconds after the 1 to 3 digit number is entered the unit will then dial the Primary Phone Number associated with t...

Страница 13: ...Proximity Card Facility Code Day of week Time of Day and Tenant Name The Event Log button is used to open the Event Log screen The Event Log screen shows you the time and date of each event the event...

Страница 14: ...settings 10 Factory Default The security code allows the user installer to program the K 1775 IP phone The factory set security code is 845464 V I K I N G It is recommended that the factory set secur...

Страница 15: ...th Log Errors selected the K 1775 IP will not only log all valid Keyless Entry Code and Proximity Card entry s but also log any errors or incorrect codes or non valid card reads Keyless Entry Code and...

Страница 16: ...rm Mode When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered and reg istered to the SIP server In the event the unit loses power and or SIP registration...

Страница 17: ...automatically increase The ANC mode is useful in applications where the background noise level can change drastically such as a gas car running vs a diesel truck 32 Mic Volume Automatic Noise Cancelli...

Страница 18: ...elow If an Access code has been programmed enter the Access code digits With the correct code entered two beeps will be heard and you can now enter the Remote Access Operation Commands below With the...

Страница 19: ...ovide keyless entry The K 1775 IP can be programmed with a combination of up to 1000 keyless entry codes or one time use keyless entry codes The keyless entry codes can be programmed to be from 1 to 6...

Страница 20: ...communications Note The VE 3x5 is not compatible with the VE GNP pedestals The VE PNL s are VE Series backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to m...

Страница 21: ...Proximity Card Readers The PRX C and PRX C ISO are non contact security cards that can be presented to the front of a K 1770 75 IP proximity card reader to allow entrance into a secured area The PRX C...

Страница 22: ...YEAR LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials under normal use and service for a period of two years from the date of purchase from any au...

Отзывы: