background image

4

Features Overview

MAC:

18E80FXXXXXX

asdesaxtff

N.C. (Gray)

N.O. (Yellow)

COM. (Blue)

* On-Board 2 Amp 

Relay Output Contacts

(2A@30VDC/ 250VAC max)

3 Gel-Filled Butt

Connectors 

(included)

- Black

+ Red

Request for Exit

 (

REX Input

)

Speaker

Microphone

MAC  Address  Label: 

The 

MAC  address  is  aunique  12 
digit number used by routers 
to send network traffic to the 
correct IP address.

PoE  LAN  Port  10/100,  PoE 
Class 1 (<4 Watts): 

Connect 

to  your  LAN  via  RJ45  plug 
and  CAT5  or  greater  twisted 
pair wire.

Yellow  Network  Status  LED: 

Lights steady to indicate power 
and data link. Blinks to indicate 
network activity.

Motion  Sensor  Sensitivity 
Adjustment  Pot: 

Sensitivity 

can  be  adjusted  from  1  to  4 
inches. Factory set to 4 inches 
(fully clockwise)

Green Unit Status LED

To Motion Sensor

Rear (PCB) View of E-20/30/32TF-IP Entry Phone

Green

Green

Yellow

Yellow

(Power typically not

required for gate controllers)

Doorstrike / 

Magnetic Lock

120V AC

Connect to Optional 

Doorstrike, Mag Lock, 

Gate Controller, etc.

(not

connected)

Note:  

The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a 

maximum insulation of 0.082 inches. Cut off stripped wire ends before terminating.

* Note:  

The front panels of the 

E-30/32TF-IP

 are mounted using security Torx screws to help prevent intruders from removing 

the panel and accessing the on board door strike/gate control relays. For applications requiring additional security, a Viking 
model 

RC-4A

 remote relay controller can be used. The relay controller is mounted securely inside the building and connected 

to the same LAN as the 

E-30/32TF-IP

. For more information on the 

RC-4A 

Secure Relay Controller, see 

DOD 582

.

Содержание E-20TF-IP

Страница 1: ...SE TX with auto cross over Regulatory Compliance FCC Part 15 Canada ICES 3 Class A CE except for E 20TF IP and E 20TF IP EWP Connections 1 RJ45 10 100 Base T 3 gel filled butt connectors Installation...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer...

Страница 4: ...LED To Motion Sensor Rear PCB View of E 20 30 32TF IP Entry Phone Green Green Yellow Yellow Power typically not required for gate controllers Doorstrike Magnetic Lock 120V AC Connect to Optional Doors...

Страница 5: ...5 22 3 25 Rear View of VE 5x5 not included 5 0 Typical 2 0 2 x 0 43 slots for single gang box 4 0 2 x 0 43 slots for double gang box 3 0 3 3 3 0 Wall Stud Front View of Plastic Rough In Box included V...

Страница 6: ...uded 5 0 Typical Peel paper liner and adhere gasket to back of panel centering over mounting holes Caution For rough surfaces ie brick stucco etc additional caulking may be required Laser Etched Graph...

Страница 7: ...5 7 8 9 10 11 12 6 STATUS LED Optional Viking model RC 4A Secure Remote Relay Controller see page 8 DOD 582 y PC Programming Download and install the programming software 1 Go to www vikingelectronics...

Страница 8: ...allowing you to trouble shoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected t...

Страница 9: ...Settings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values fo...

Страница 10: ...t will start slow flashing the LED when your hand is detected After 3 seconds 2 beeps should be heard and the LED will start fast flashing Immediately remove your hand from covering the sensor LED sho...

Страница 11: ...ctory set to 5 20 16 Microphone Volume 0 9 0 Auto factory set to 5 21 17 Talk Listen Delay VOX 0 1 0 9 seconds factory set to 0 5 seconds 22 17 In Band Audio Call Progress Enabled Disabled factory set...

Страница 12: ...erver and alternate SIP server will be limited to 31 characters Note If outbound proxy is not required enter the SIP server IP address into the Outbnd Proxy field 2 SIP Server When set to the Peer to...

Страница 13: ...y personnel to identify the location of the caller and is given out when the receiving party presses a Q This ID number is transmitted as In Band DTMF This can be cleared out by leaving the field blan...

Страница 14: ...or from the Emergency Entry phone This mode is useful for turning on IR flood lights VoIP phones with cameras etc Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activate t...

Страница 15: ...ressing the button again after the call has been initiated will not terminate the call Factory Setting Enabled 17 Alternating Switch Action Panic Button Mode When set to Ring or Ring with AGC The Entr...

Страница 16: ...rnatively the microphone can be placed in the Auto Automatic Noise Cancelling mode With the mic in the Auto mode when background noise increases the mic gain will automatically decrease When backgroun...

Страница 17: ...o answer require the callers to dial the access code in order to transmit a page activate the relay or activate the optional RC 4A relays Factory Setting Auto Answer Disabled Inbound SIP calls are not...

Страница 18: ...ifferent modes Factory Setting Entry Phone OFF Mode Useful for silent monitoring applications In this mode the motion sensor LED will not light during normal operation It will only flash ON OFF Blue i...

Страница 19: ...e relay in the Doorstrike Mode when the push button swith is pressed the relay will be activated to open the door 42 REX Input 36 IP Firmware If new Entry Phone firmware is available after opening the...

Страница 20: ...Remote Access Operation Commands Feature Tone Tone Command Description Activate Relay QQ or ___ ___ Momentarily activate relay 1 or 2 digits factory set to QQ Un Latch Relay Q0 Un latch deactivate th...

Страница 21: ...netic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30V...

Страница 22: ...ommunications Note The VE 3x5 is not compatible with the VE GNP pedestals The VE PNL s are VE Series backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to mou...

Страница 23: ...to the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the l...

Отзывы: