10
E. Manually Resetting the Security Code to Enter Programming
F. Manually Resetting All Network Parameters to Factory Default
Step 1.
Click on the “VLAN” tab
Step 2.
Disable or enable VLAN tagging by setting the value of “VLAN Tagging”.
Step 3.
Set the VLAN tag ID by selecting an integer (1 to 4094) in “ID for all packets”.
Step 4.
Set the Priority Code Point (PCP) value for all not SIP and RTP packets in the “PCP for all packets” input (0 is default, priorities are
from low to high: 0, 1, 2, 3, 4, 5, 6, 7). Set the “PCP for SIP packets” (3 is default). Set the “PCP for RTP packets” (5 is default).
D. Configuring E-20/30/32TF-IP VLAN Settings
Step 1.
Power down the
E-20/30/32TF-IP
phone by disconnecting the LAN
Cable (RJ45 plug) then reconnect the LAN
Cable (RJ45 plug).
Step 2.
A few seconds after reconnecting the LAN
Cable the motion sensor LED will light steady green for 2 seconds. When the LED lights
steady green, immediately cover the sensor with your hand for 3 seconds. The unit will start slow flashing the LED when your hand is
detected. After 3 seconds, 2 beeps should be heard and the LED will start fast flashing. Immediately remove your hand from covering
the sensor. LED should stop flashing and light steady blue.
Step 3.
The security code is now reset to
845464
(factory default).
Step 4.
You can now enter programming by following the steps in section
A
.
Step 1.
Power down the
E-20/30/32TF-IP
phone by disconnecting the LAN
Cable (RJ45 plug) then reconnect the LAN
Cable (RJ45 plug).
Step 2.
A few seconds after reconnecting the LAN
Cable the motion sensor LED will light steady green for 2 seconds. When the LED lights
steady green, immediately cover the sensor with your hand. The unit will start slow flashing the LED when your hand is detected. After
3 seconds, 2 beeps should be heard and the LED will start fast flashing. Continue to cover the sensor for 6 more seconds. The unit
should output 4 beeps and the LED should stop flashing and light steady blue.
Step 3.
The security code is now reset to
845464
and all network parameters are set to factory default.
Step 4.
You can now enter programming by following the steps in section
A
.