background image

17

If enabled and a busy is detected, the speaker phone will dial the next programmed Speed Dial number. A momentary 
press of the call button will dial the first programmed phone number. 

Factory Setting:

 Enabled

30. Dial Next Number on Busy 

31. Send ID Number as

29. Dial Next Number on Ring No Answer

If enabled and a ring-no-answer is detected, the 

Entry Phone

 will dial the next programmed Speed Dial number after 

the programmed amount of rings. A momentary press of the call button will dial the first programmed Speed Dial number. 

Factory Setting: 

7 (will redial after 7 rings)

 The I.D. number can be transmitted as RFC 2833 or as In-Band DTMF. 

Factory Setting:

 RFC 2833

28. Ring Cadence

The Ring cadence can be programmed to one of 4 different cadences. 

Factory Setting: 

Normal 

Normal Ring 

(single ring, 2 seconds on 4 seconds off)  

Double Ring

 (double ring, 1 second on 0.5 seconds off 1 second on 3.5 seconds off) 

Short-Short-Long

 (triple ring, 0.5 seconds on 0.5 seconds off 0.5 seconds on 0.5 seconds off 1 second on 3 seconds off) 

Short-Long-Short

 (triple ring, 0.5 seconds on 0.5 seconds off 1 second on 0.5 seconds off 0.5 seconds on 3 seconds off)

The Inbound Call Mode determines how the 

Entry Phone

 handles incoming SIP calls.  One option is to generate a 

loud ring sound through the speaker. The 

Entry Phone

 can also auto answer a SIP call to transmit a page, control  the 

relay or listen to transmit audio from the microphone.  The last option is the silent monitor mode, which allows callers 
to listen to the transmit audio from the microphone.  The “secure” options for auto answer require the callers to dial the 
access code in order to transmit a page, activate the relay or activate the optional 

RC-4A

 relays. 

Factory Setting: 

Auto Answer 

Disabled

 – Inbound SIP calls are not allowed. 

Auto Answer

 – Inbound SIP calls are auto answered on the first ring. This can also be used for Silent Monitoring by 

changing the speaker mode to ‘OFF/Silent Monitor”, See page 16. For more security use the Auto Answer Secure 
Mode. 

Auto Answer Secure

 – In the “Auto Answer - Secure” mode, the phone will automatically answer an incoming call on 

the first ring. The unit will then output 2 beeps but will not go into two-way voice mode. After the 2 beeps are heard, 
you will have 10 seconds to enter the pre-programmed 1 - 6 digit Access Code (see section 10 on page 14). When the 
correct code in entered, 2 beeps will be heard and the unit will enable the Two-Way Mode (mic and speaker audio). 
After the correct Access Code is entered, any of the “Remote Access Operation Commands” can be used (see 
Operation, section B on page 21). 

Note: 

If the wrong Access Code is entered or more than 10 seconds have elapsed, 

the phone will output 3 beeps and disconnect.

 

Ring:

 In the “Ring” mode the speaker phone will not automatically answer an incoming call but will output a loud ring 

signal out of the speaker in a 2 seconds on, 4 seconds off ring pattern. There are four available ring cadences. 

Ring with AGC:

 In the “Ring with AGC” mode the speaker phone will not automatically answer an incoming call but 

will output a loud ring signal out of the speaker in a 2 seconds on, 4 seconds off ring pattern. The phone will 
automatically increase or decrease the ring volume based on background ambient noise. The call can then be answered 
by momentarily pressing the call button.

 

27. Inbound Call Mode

Содержание E-20TF-IP

Страница 1: ...SE TX with auto cross over Regulatory Compliance FCC Part 15 Canada ICES 3 Class A CE except for E 20TF IP and E 20TF IP EWP Connections 1 RJ45 10 100 Base T 3 gel filled butt connectors Installation...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer...

Страница 4: ...LED To Motion Sensor Rear PCB View of E 20 30 32TF IP Entry Phone Green Green Yellow Yellow Power typically not required for gate controllers Doorstrike Magnetic Lock 120V AC Connect to Optional Doors...

Страница 5: ...5 22 3 25 Rear View of VE 5x5 not included 5 0 Typical 2 0 2 x 0 43 slots for single gang box 4 0 2 x 0 43 slots for double gang box 3 0 3 3 3 0 Wall Stud Front View of Plastic Rough In Box included V...

Страница 6: ...uded 5 0 Typical Peel paper liner and adhere gasket to back of panel centering over mounting holes Caution For rough surfaces ie brick stucco etc additional caulking may be required Laser Etched Graph...

Страница 7: ...5 7 8 9 10 11 12 6 STATUS LED Optional Viking model RC 4A Secure Remote Relay Controller see page 8 DOD 582 y PC Programming Download and install the programming software 1 Go to www vikingelectronics...

Страница 8: ...allowing you to trouble shoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected t...

Страница 9: ...Settings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values fo...

Страница 10: ...t will start slow flashing the LED when your hand is detected After 3 seconds 2 beeps should be heard and the LED will start fast flashing Immediately remove your hand from covering the sensor LED sho...

Страница 11: ...ctory set to 5 20 16 Microphone Volume 0 9 0 Auto factory set to 5 21 17 Talk Listen Delay VOX 0 1 0 9 seconds factory set to 0 5 seconds 22 17 In Band Audio Call Progress Enabled Disabled factory set...

Страница 12: ...erver and alternate SIP server will be limited to 31 characters Note If outbound proxy is not required enter the SIP server IP address into the Outbnd Proxy field 2 SIP Server When set to the Peer to...

Страница 13: ...y personnel to identify the location of the caller and is given out when the receiving party presses a Q This ID number is transmitted as In Band DTMF This can be cleared out by leaving the field blan...

Страница 14: ...or from the Emergency Entry phone This mode is useful for turning on IR flood lights VoIP phones with cameras etc Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activate t...

Страница 15: ...ressing the button again after the call has been initiated will not terminate the call Factory Setting Enabled 17 Alternating Switch Action Panic Button Mode When set to Ring or Ring with AGC The Entr...

Страница 16: ...rnatively the microphone can be placed in the Auto Automatic Noise Cancelling mode With the mic in the Auto mode when background noise increases the mic gain will automatically decrease When backgroun...

Страница 17: ...o answer require the callers to dial the access code in order to transmit a page activate the relay or activate the optional RC 4A relays Factory Setting Auto Answer Disabled Inbound SIP calls are not...

Страница 18: ...ifferent modes Factory Setting Entry Phone OFF Mode Useful for silent monitoring applications In this mode the motion sensor LED will not light during normal operation It will only flash ON OFF Blue i...

Страница 19: ...e relay in the Doorstrike Mode when the push button swith is pressed the relay will be activated to open the door 42 REX Input 36 IP Firmware If new Entry Phone firmware is available after opening the...

Страница 20: ...Remote Access Operation Commands Feature Tone Tone Command Description Activate Relay QQ or ___ ___ Momentarily activate relay 1 or 2 digits factory set to QQ Un Latch Relay Q0 Un latch deactivate th...

Страница 21: ...netic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30V...

Страница 22: ...ommunications Note The VE 3x5 is not compatible with the VE GNP pedestals The VE PNL s are VE Series backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to mou...

Страница 23: ...to the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the l...