34. Mute Current / Next Alarm
A network failure alarm will be indicated by providing 3 beeps every 30 seconds. A network failure indicates the unit is
not registered to the SIP server or there is a communication failure with the gateway. The three beeps can be muted
by clicking on “Mute Current / Next Alarm”. The Status LED will continue to flash to assist troubleshooting. The alarm
beeps can also be permanently disabled. See Permanent Alarm Mute.
During outbound SIP calls the “CALL” (Motion Sensor) LED can be programmed to light steady Green automatically
when the called party has answered or only light steady Green after the called party has entered a touch tone “
Q
”
.
Factory Setting:
Automatic
33. “Call” (Motion Sensor) LED
Control
32. Call (Motion Sensor) LED Mode
The “Call” (Motion Sensor) LED on the
E-20/30/32TF-IP
can be programmed to one of four different modes.
Factory Setting:
Entry Phone
OFF Mode:
Useful for silent monitoring applications. In this mode the motion sensor LED will not light during normal
operation. It will only flash ON/OFF Blue if it cannot register with the programmed SIP server or while manually resetting
all network parameters to factory default.
Entry Phone Mode:
The motion sensor LED will remain steady Blue in the idle state, flash Green during dialing, light
steady Green when the call is answered, then turn back to steady Blue when the call is completed.
Emergency Phone Mode:
The motion sensor LED will remain OFF in the idle state, flash green during dialing, light
steady Green when the call is connected, then turn OFF when the call is completed.
Emergency Phone Outbound Only:
On outbound calls, the motion sensor LED will remain OFF in the idle state,
flash Green during dialing, light steady Blue when the call is connected, then turn OFF when the call is completed. On
in-bound calls, the LED will remain off. This is useful for silent monitoring on inbound calls.