31
Port Configuration Window
Port Configuration
1.15.1 Port
1.15.2 Detection
Type
The “Port Configuration” window enables the ability to configure a single port and
view its status.
Figure 21: Port Configuration
Select the port number to be changed or status viewed.
Selects the PD detection type to be used:
“None” for bypassing detection.
“2-point” for 2-point detection.
“4-point” for 4-point detection.
“4-point+legacy” for 4-point followed by legacy.
“2-point+legacy” for 2-point followed by legacy.
“Legacy” for legacy detection only.
The “Legacy” option will be considered the next time a “detection" is performed on
a port. This will not affect ports currently in a power delivering state. To apply a
change of the detection type, disable and then enable the port.