1.11.2 ILIM/ICUT
Configuration
1.11.3 System
Configuration
1.11.4 Chip ID
1.11.5 SW Version
For
Normal Mode,
the power budgeted is 16.2W:
For High Power Mode (802.3at-Class 4) the power budgeted is based on
ILIM/ICUT selected value.
o
For ILIM/ICUT – 504/465 mA, the power budgeted is 22.5W.
o
For ILIM/ICUT – 563/545 mA, the power budgeted is 26.5W.
o
For ILIM/ICUT – 850/625 mA, the power budgeted is 31.6W.
o
For ILIM/ICUT – 850/725 mA, the power budgeted is 37.0W.
These limits will help to provide the necessary power for your system and
prevents run away shorting and potential damage from occurring.
Static /wo Priority:
Same as above except that port priority of the port is
ignored.
Static /wo Priority:
Power is budgeted statically based on selected violation
type.
o
If violation type is “
Class Based
”, then maximum permissible
power for that class is budgeted.
o
If violation type is “
User Defined
”, then the configured user-
defined limit is budgeted.
o
If violation type is “
None
”, then budgeted power is based on port
mode.
For
Normal Mode,
the power budgeted is 16.2W:
For High Power Mode, the power budgeted is based on ILIM/ICUT selected
value.
For ILIM/ICUT – 504/465 mA, the power budgeted is 22.5W.
For ILIM/ICUT – 563/545 mA, the power budgeted is 26.5W.
For ILIM/ICUT – 850/625 mA, the power budgeted is 31.6W.
For ILIM/ICUT – 850/725 mA, the power budgeted is 37.0W.
Dynamic /w Priority:
The power is budgeted based on the load and priority
of the port.
Dynamic /wo Priority:
The power is budgeted based on the Load.