25
1.11.6 Max Ports
1.11.7 Power
Available
1.11.8 Power
Allocated
1.12.1 Commands
1.12.2 Query
1.12.3 Apply
1.12.4 Delayed
Power up
1.12.5 Port
1.12.6 0-240
1.12.7 Enable All
Ports
1.12.8 Disable All
Ports
1.12.9 Set delay
time for all ports
This shows the maximum number of Midspan ports detected by the software.
This shows the total available power for the Midspan.
This shows the total power allocated by the system. Power allocated varies based on
the power management mode selected.
Click the “Query” button to update the status fields.
Click the “Apply” button to configure the system with the inputted values.
The delayed Power up section gives the user the ability to prevent all ports from
turning on at the same time following a power failure. This will prevent any large
current surges on the AC power that supplies the Midspan. Each port can be
programmed with a delay time starting from the point the Midspan finishes booting
up and ending with the port delivering PoE power. This delay can be anywhere from
0 to 240 seconds. During this delay time the PoE LED’s with will flash on any ports
that have a valid load attached. This is to show that the Midspan port(s) are in delay
mode and will be powered once the delay time has expired.
Signifies the port number that corresponds to the controls.
The port delay can be enabled or disabled according to the selection from the drop
down menu. When “Disabled” is selected “0” will always be displayed as the delay
time. If “Enabled” is selected, the delay time can be set. Zero will act the same as
disabling the port. Selecting 1-240 will set a delay period. Clicking the “Query”
button will display the individual port time delay that is currently programmed in the
Midspan, only if “Enabled” is selected.
When clicked, this button will set all ports to “Enabled”.
Clicking this button will disable all ports and set the delay time to 0.
By changing this setting, the value will be applied to all ports.