User’s Manual 

 

MaxiiPower

TM

 Vi2208A & Vi2216A 

High Powered PoE Midspans UTP 
 

MaxiiPower

TM

 Vi2508 & Vi2516 

High Powered Midspans UTP Extenders 

MaxiiPower

TM

 Vi2608 & Vi2616 

High Powered Midspans Ethernet to Coax Extender 

 

Version 1.2 Updated 10/07/2015 

 

 

Содержание MaxiiPower Vi2208A

Страница 1: ...stered trademarks of their respective companies User s Manual MaxiiPowerTM Vi2208A Vi2216A High Powered PoE Midspans UTP MaxiiPowerTM Vi2508 Vi2516 High Powered Midspans UTP Extenders MaxiiPowerTM Vi2...

Страница 2: ...System Requirements 15 GUI Graphical User Interface Installation Procedure 16 Midspan Default Network 21 Username and Password 21 Firmware Window 21 System Configuration Window 23 1 11 1 Power Manage...

Страница 3: ...13 9 Select All 28 1 13 10 Apply 28 System View Window 29 1 14 1 Poll 29 1 14 2 Power Available 29 1 14 3 Port Allocated 29 1 14 4 Power Delivering 29 1 14 5 Port 30 1 14 6 Port Status 30 1 14 7 Port...

Страница 4: ...dspan IP Address Programmer 36 1 18 6 Program New Midspan IP Address 36 1 18 7 GUI IP Address List 36 1 18 8 Add IP Address Description 36 1 18 9 Delete Selected IP Address 36 SNMP Simple Network Mana...

Страница 5: ...8s Vi2516s Rear View 10 Figure 9 Vi2508 Vi2516 Rear View 10 Figure 10 Vi2516 Application Drawing 10 Figure 11 Vi2616 Vi2616s Front View 10 Figure 12 Vi2608 Vi2608s Front View 11 Figure 13 Vi2608s Vi26...

Страница 6: ...re that the external power supply output voltage is in the recommended range Do not install near any heat sources such as radiators heat registers stoves or other apparatus including DVRs that produce...

Страница 7: ...7...

Страница 8: ...C and provides configuration power supervision monitoring and diagnostics of all ports through either Ethernet or a USB port The MaxiiPower Midspans are 1U height and can be easily installed in 19 rac...

Страница 9: ...9 Figure 4 Vi2216 Application Drawing Figure 5 Vi2516 Vi2516S Front View Figure 6 Vi2508 Vi2508S front view Figure 7 Redundant Power Supply Connector Pin Out...

Страница 10: ...10 Figure 8 Vi2508S Vi2516S Rear View Figure 9 Vi2508 Vi2516 Rear View Figure 10 Vi2516 Application Drawing Figure 11 Vi2616 Vi2616S L Front View...

Страница 11: ...13 Vi2608S Vi2616S L Rear View Figure 14 Vi2608 Vi2616 Rear View Figure 15 Vi2616 Application Drawing Note The Vi2616L and Vi2616SL models are only compatible with Vi2400AL 2401AL Extenders Models en...

Страница 12: ...and 2301A can be used with the Vi25xx series Midspans while models Vi2400A and Vi2401A are compatible with the Vi26xx series Connect the RJ45 cables from the Ethernet switch to the Standard Ethernet...

Страница 13: ...Lower row Link Orange On Connection is good Traffic Green Flashing Data is being sent Vi25xx Series LED Name Color Status Function PoE Orange Off No power provided On Delivering power Flashing Fault...

Страница 14: ...Hz 6 5 A max Output Status LED Green LED Connectors Ethernet Input Interface Shielded RJ 45 Ethernet Output Interface Shielded RJ 45 AC Power IEC380 8 inlet Redundant power 5 pin circular connector V...

Страница 15: ...the PD UTP Midspans are compatible with models Vi2300A and Vi2301A while coax Midspans use models Vi2400A and Vi2401A The Midspans are set to Auto mode by the factory In this mode the Midspan works as...

Страница 16: ...y not update the USB port driver automatically You may need to update the driver manually as followings A Window XP Go to System property Hardware Device manager USB Serial converter and update driver...

Страница 17: ...e Ports icon and a list of ports will be displayed along with a brief description The following example shows COM 50 as being a USB serial port The Midspan is connected to this port Now you can go bac...

Страница 18: ...18 Common issues that prevent a successful connection are not having the USB driver installed incorrect port selection or not powering up the Midspan...

Страница 19: ...hat will be used to connect to the Midspan Step 2 Locate any Midspans on your network Click on Find all Midspan IP Addresses A list of Midspan IP Addresses will appear in the window Select the Midspan...

Страница 20: ...to Midspan To connect to the Midspan click on the down arrow under Midspan IP Address Click on the appropriate Midspan address Verify Ethernet is selected under Connection Method Click Connect under M...

Страница 21: ...n enter in a new user name and password and then click Change Username and Password to update the login information Firmware Window Warning Upgrading firmware is not part of the normal operating proce...

Страница 22: ...mand will be downloaded to the Midspan and replaced the current firmware Clear Image Caution only click this button when prompted to do so When connected to a Midspan this button will delete the exist...

Страница 23: ...used in the following modes None Indicates Power Management will not be performed by the firmware User needs to power up the ports manually Static w Priority Power is budgeted statically based on sel...

Страница 24: ...ype o If violation type is Class Based then maximum permissible power for that class is budgeted o If violation type is User Defined then the configured user defined limit is budgeted o If violation t...

Страница 25: ...a delay time starting from the point the Midspan finishes booting up and ending with the port delivering PoE power This delay can be anywhere from 0 to 240 seconds During this delay time the PoE LED s...

Страница 26: ...n configured with the desired delay time A message box will then appear as shown below It is always necessary to save the configuration in the Firmware tab to ensure that your changes are not lost fro...

Страница 27: ...es If your device does not turn on try changing this setting Choose the detection type to be used for selected ports matching it to the camera requirements Most cameras will work in the default positi...

Страница 28: ...ined Acceptable wattage inputted is 0 51 Watts Choose the Power Inrush Control mode of selected port Normal for IEEE 802 3af mode High Inrush for Legacy devices which require more than 15 4W For port...

Страница 29: ...a single screen Figure 20 System View Window If the Poll box is checked it will enable continuous refreshing of the parameters This box shows the Midspan total available power The total power allocat...

Страница 30: ...the port status The status is color coded as following for easy identification Green Delivering Blue Searching Gray Disabled Yellow Requesting Power Orange Test mode Red Fault The power currently bei...

Страница 31: ...the PD detection type to be used None for bypassing detection 2 point for 2 point detection 4 point for 4 point detection 4 point legacy for 4 point followed by legacy 2 point legacy for 2 point follo...

Страница 32: ...ess critical ports can be set with a lower priority Ports with the priority set to 3 have the highest priority and 0 is the lowest Selects the violation type to be used by the port during delivering s...

Страница 33: ...led Yellow for Requesting Power Orange for Test mode Red for Fault This shows the class being detected in case of normal operation Also it shows the error value in case of a fault condition This shows...

Страница 34: ...n Counter 1 17 5 Reset Statistics This shows how many times the port has been in overload status This shows how many times the port has been shorted This shows how many times the port has denied power...

Страница 35: ...e the IP Address Default Gateway and Subnet Mask of a Midspan Figure 22 IP Address Configuration This is used to determine the Host computer IP address Note Some computers have more than one IP Addres...

Страница 36: ...he data and then clicking on Program Midspan IP Address This section is used to add IP addresses to the drop down list under Midspan IP Addresses These IP Addresses are used to connect the GUI running...

Страница 37: ...Any Midspan being monitored with SNMP should not be accessed by another GUI Doing so can create false information An SNMP trap program is needed to receive and view the SNMP messages sent by the Mids...

Страница 38: ...19 2 Creating a List of Midspans to be Monitored with SNMP SNMP Midspan List Any Midspan to be monitored through SNMP must be listed in this textbox Use the Add or Add All buttons to populate the Tex...

Страница 39: ...s button all IP addresses in the Midspan IP Address drop down box will be inserted into the SNMP Midspan List A maximum of 21 addresses can be listed Delete To remove a single IP address from the SNMP...

Страница 40: ...atically loaded when the GUI is restarted Load configuration This button will load a previously saved SNMP configuration Error Check If a Midspan IP address or description is changed it is important t...

Страница 41: ...default this box is checked Checking this box will enable tool tips By placing your mouse over an SNMP control a message will appear with a brief description of the controls operation By default this...

Страница 42: ...t supply power Port Forced Pwr This message is sent when the port is configured in the GUI to send power regardless of any connected device Port Power Req This message is sent when the port is connect...

Страница 43: ...are consumed providing the ability to power four additional 60 watt cameras This can be accomplished using the Vi0015 cable which combines the power of two ports while maintaining the standard wiring...

Страница 44: ...tted by law Vigitron its dealers distributors and other appointed agencies hereby disclaim all warranties whether expressed or implied including and without limitations warranties that the product is...

Страница 45: ...lifornia U S A excluding its conflict of law provisions It is further agreed that if one or more provision of this agreement are held to be illegal or unenforceable under applicable California law suc...

Страница 46: ...of equal value This warranty does not apply if in the judgment of Vigitron Inc the Product fails due to damage from shipment handling storage accident abuse or misuse or if it has been used or maintai...