Keep the communication cables at least 50 meters away from high
voltage equipment or cables.
Make outdoor cable laying-out under eaves as possible as you
can.
In open area shield cables in steel tube and conduct a single point
ground to the tube. Trolley wire is forbidden in such circumstances.
In strong thunderstorm or high faradic zone (such as high voltage
transformer substation), extra strong lightning proof equipment
must be installed.
Take the building lightning proof requirements into account to
design the lightning proof and grounding of outdoor equipment and
cable laying-out in accordance with the national and industrial
standards.
The system must be grounded with equal potentials. The earth
ground connection must satisfy the anti-interference and electrical
safety requirements and must not short circuited with high voltage
electricity net. When the system is grounded separately, the
resistance of down conductor should be
≤
4
Ω
and the sectional
area of down conductor should be
≤
25
mm
2
(refer to Picture 59)
-30303030
30