function switch
able
Table 7
7. Troubleshooting
Problems
Possible Causes
Remedies
No action when
power is
switched on
Power supply fault
Replace
Bad connection of the power
Correct
Transformer damaged
Replace
Abnormal self-
check. Images
with motor
noise
Mechanical failure
Repair
Camera inclined
Reinstall
Power supply not enough
Replace
Normal self-
check but no
images
Video signal fault
Reinstall
Bad connection of the video
Press to connect well
Camera damaged
Replace
Normal self-
check but out of
control
RS485 bus bad connection
Check the RS485
connection
Dome ID setup is wrong
Reselect
Protocol setup is wrong
Reset and Switch
ON again
Vague image
Bad connection of the video
Press to connect well
Power supply not enough
Replace
Dome camera
out of control
Self check error
Switch ON again
Bad connection of control
Press to connect
well
Bad control of matrix
Switch ON again
Table 8
Appendix
Ⅰ
: Lightning Proof and Surge Signal Proof
The product adopts TVS lightning proof technology to prevent from
damage by lightning strike below 1500 W and impulse signals such
as surge; but it is also necessary to abide by the following
precautions to ensure electrical safety based on practical
circumstances:
-29292929