18
5833 275 - 04
Vitotrans 300 Installation, Operating and Service
Installation
Preparing the Unit for Installation
Unpacking and Placing the Unit
1.
Remove the Vitotrans from the wooden shipping
pallet. Remove the 4 leveling bolts
A
from boiler’s
accessory package and install into the four corners of
the boiler base.
Note:
When using seismic brackets
B
(optional
accessory) do not install levelling bolts.
2.
It is recommended to place a flat piece of steel plate
under each leveling bolt for better weight distribution
and adjustment.
3. Level the Vitotrans 300 with a slight slope towards
the base pan drain opening, by adjusting the floor
levelling
bolts.
Note:
It is recommended that the levelling bolts included
with the boiler are used when installing the
Vitotrans on uneven surfaces.
Refer to the Seismic bracket Installation
Instructions when using the optional seismic
mounts.
It is essential to use appropriate lifting devices
certified for lifting to a minimum of the Vitotrans
weight.
Remove the packaging from the Vitotrans.
The Vitotrans can be positioned using a forklift, using
the openings provided on the front, rear and sides.
CAUTION
Take care to ensure unit is not damaged by the forklift
during lifting.
Legend
A
Crane lifting provisions (two on each side)