85
Type BWC in conjunction with "conversion kit for water/
water heat pump"
301.C06
301.C12
301.C16
Brine
(primary intermediate circuit)
Capacity
l
3.7
4.2
5.5
Minimum flow rate
l/h
1220
1520
1800
Residual head at minimum flow rate
mbar
750
660
590
kPa
75.0
66.0
59.0
Max. flow temperature (brine inlet)
°C
25
25
25
Min. flow temperature (brine inlet)
°C
7.5
7.5
7.5
Heating water
(secondary circuit)
Capacity
l
4.5
5.3
6.7
Minimum flow rate
l/h
490
600
1100
Residual head at minimum flow rate
mbar
720
705
650
kPa
72.0
70.5
65.0
Max. flow temperature
°C
65
65
65
Note
Further specifications: See "Specification for brine/
water heat pumps".
Specification
Specification for water/water heat pumps