Spec
Sheet
ECOTRONIC
-
Heating
Control
Unit
Heat Consumers
Köb Holzheizsysteme GmbH, Flotzbachstr. 33, A-6922 Wolfurt, Tel. +43/5574/6770-0, Fax 65707, E-Mail: [email protected]
Subject to technical changes
4040-1
2009-03-01_GB
Controller for Room Heating Units
[Art. No. ECO-H / 7379402]
A weather-guided heating control system with a digital timer for lowerable operation
according to daily or weekly schedules, with pump control system, frost-protection
function, ECO mode and limited flow temperature.
Scope of delivery:
-
Pushbutton for heating
-
Controller output for pump (1) and mixing valve (2)
-
Flow sensor QAD 21, uninstalled
Controller for Annex Buildings
[Art. No. ECO-N / 7387865]
Function:
The pipelining is usually loaded with a lowered temperature according to the weather-
guided heating control system. The charging of the utility water heater is carried out with
the maximum set supply temperature. To do this the hot water is diverted by a valve to
the utility water heater. This is extended to ancillary time periods by the integrated timer,
whereby the room unit will be interrupted for a short time.
Scope of delivery:
-
Pushbutton for annex building
-
Controller output for pump (1), mixing valve (1) and changeover valve (3)
-
Flow sensor QAD 21, uninstalled
-
Domestic water sensor QAZ 21.5220 with dipping shell ½" x 200 mm, uninstalled
Thermostat QAA 35
[Art. No. ECO-ZR-QA / 7379405]
Thermostat QAA 35, uninstalled; a supplement to the Controller for Room Heating Units (Art.-
No. ECO-H) and Controller for Annex Buildings (Art. No. ECO-N). The Thermostat can be
connected as a remote control device and as a room sensor (room temperature compensation).
Safety Thermostat RAK-TW.1000B
[Art.-No. ECO-ZR-RA / 7387940]
Safety Thermostat SB 2592, uninstalled
To safely and reliably limit the flow temperature of a heating circuit
(e.g. ECO-H, ECO-N, ECO-F).
Controller for Pipelining
[Art. No. ECO-F / 7379401]
For annex buildings with separate heat distributions systems, which are supplied with heat
via pipelining. The temperature of the pipeline is pre-adjusted for the lowest line losses
according to the heat distribution requirement.
Scope of delivery:
-
Pushbutton for pipelining
-
Controller output for pump (1) and control valve (2)
-
Flow sensor QAD 21, uninstalled
Note:
The Controller for Pipelining cannot be used to control a pipeline to which heating control
units provided by the customer are connected!
A normal heating control system has to be used in such cases.
SB 2592
annex
building