74
"Warnings"
HMU heat man-
agement
unit / fuel cell
module mes-
sage
System characteristics
Cause
Measures
A.5/04F0
Fuel cell module in operation
45 days until the 5-yearly
service
Carry out the 5-yearly service.
A.6/04F1
Fuel cell module in operation
30 days until the 5-yearly
service
Carry out the 5-yearly service.
A.7/06F0
Fuel cell module in operation
3 months until required re-
pair
Schedule repair.
A.8/08F0
Fuel cell module in operation
6 months until decommis-
sioning (after 20 years of
operation)
Schedule decommissioning.
A.12
Fuel cell module in operation
Real time clock battery is
flat.
Replace battery in HMU heat man-
agement unit.
Troubleshooting
Message overview
(cont.)
5839343