70
Message
System characteristics
Cause
Measures
F.249/67F9
No power generation
Air in the distilled water
circuit
Carry out fuel cell module commis-
sioning again.
If the fault recurs, notify Viessmann
Technical Service.
Note
The message can
only
be cleared
on the programming unit of the fuel
cell module.
F.294/9BF0
No power generation
Blockage in the flue sys-
tem
Check flue system.
Note
Reset the message on the fuel cell
module programming unit.
Then switch the ON/OFF switch of
the fuel cell module OFF for ap-
prox. 10 s and ON again.
F.296/A8F0
No power generation
Gas pressure too low
Gas supply interrupted
Check the gas supply.
F.297/A9F0
No power generation
Gas pressure too high
Check the gas supply.
F.299
Wrong time
Real-time clock fault
Set the time.
Check battery in HMU heat man-
agement unit.
F.303/C2F0
No power generation
Fault, stack voltage 1 (fuel
cell)
■
Check the balanced flue system
for:
–
Flue gas recirculation
–
Leaks
■
Check ventilation air supply for:
–
Ingress of flue gas due to insuf-
ficient clearance from,
for example, the flue system of
a solid fuel boiler
–
Outgassing/contamination in
the air supply system (e.g. sili-
cones, oils, paints, detergents,
deposits, etc.)
If the fault recurs, contact
Viessmann Technical Service.
Note
The fault message can
only
be
cleared on the programming unit of
the fuel cell module.
Troubleshooting
Message overview
(cont.)
5839343
Diagnosis