68
"LON communication module: Fault manager"
Setting
Explanations
Control unit is not fault manager
79:0
Control unit is fault manager
79:1
"LON communication module: time"
Setting
Explanations
Control unit does not transmit the time
7B:0
Control unit transmits the time
7B:1
"Chimney connection"
Setting
Explanations
Single connection
7E:0
One boiler connected to the flue system
Multiple connections
7E:1
Several boilers connected to one shared flue system
"Building type"
Setting
Explanations
Apartment building. Holiday program and
time program for DHW heating can be set
separately.
7F:0
Detached house. One holiday program and
one time program for DHW heating
7F:1
"Fault messaging delay"
Setting
Explanations
80:6
If a fault occurs for at least 30 s, a fault message is
displayed
None
80:0
Immediate fault message
... x 5 s
80:2 to
80:199
Delay adjustable from 10 s to 995 s
1 step
≙
5 s
"Automatic summer/wintertime changeover"
Setting
Explanations
Without automatic summer/wintertime
changeover
81:0
Time must be changed over manually
With automatic summer/wintertime change-
over
81:1
Use of the radio clock receiver (automatic
recognition)
81:2
With LON communication module: Control
unit receives the time
81:3
"Gas type (note "General" group, parameter 11)"
Setting
Explanations
Natural gas
82:0
LPG
82:1
Only adjustable if parameter 11:9 has been set
"Temperature display"
Setting
Explanations
° Celsius
88:0
Temperature indicator in the display
° Fahrenheit
88:1
Parameter level 2
General
(cont.)
5778741
Parameter