24
Required parameters
Parameter
Setting
"System definition"
■
"System scheme 7000"
"6"
"External heat source"
■
"Enable external heat source 7B00"
"1"
■
"Enable external heat source for DHW heating
7B0D"
"1"
DHW heating:
"Time program DHW"
Set time program (see oper-
ating instructions)
"Time prog. DHW circ."
(if a DHW circulation pump is installed)
Set time program (see oper-
ating instructions)
"DHW"
■
"Enable booster heaters for DHW heating 6014" "1"
■
"Enable electric heaters for DHW heating 6015"
"1"
Instantaneous heating water heater
(if installed):
"Electr booster heater"
■
"Enable instantaneous heating water heater
7900"
"1"
■
"Enable instant. heating water heater for central
heating 7902"
"0"
"Cooling"
■
"Cooling function 7100"
"3"
■
"Cooling circuit 7101"
"1"
Remote controls
(if installed):
"Heating circuit 1"
■
"Remote control 2003"
"1"
"Heating circuit 2"
■
"Remote control 3003"
"1"
To call up
"Coding level 1"
for setting
the parameters, see the commissioning
assistant on page 78 and page 80.
Preparing for installation
System example 2, ID: 4605170_1005_01
(cont.)
5724 152 GB
Содержание AWS 104
Страница 5: ...5 Certificates Declaration of conformity 119 Keyword index 120 Index Index cont 5724 152 GB...
Страница 86: ...86 Placing the control panel in its service position 4x 1 2 3 Troubleshooting Repairs 5724 152 GB...
Страница 87: ...87 Opening programming unit 3 2 1 2x Troubleshooting Repairs cont 5724 152 GB Service...
Страница 88: ...88 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5724 152 GB...
Страница 89: ...89 Removing separating plate 1 2 Troubleshooting Repairs cont 5724 152 GB Service...
Страница 98: ...98 101 300 104 231 100 232 230 105 103 103 300 A Parts lists Parts list internal unit cont 5724 152 GB...