Space requirement press rings D
½
–2
D
½
¾
1
¼
1
½
2
a [mm]
60
65
95
105
105
b [mm]
75
85
125
135
140
c [mm]
80
80
80
80
80
Minimum interval with press jaws D ⅜–1
Press machine
a
min
[mm]
Type 2 (PT2)
50
Type PT3-EH
Type PT3-AH
Pressgun 4E / 4B
Pressgun 5
Picco / Pressgun Picco
50
Minimum interval with press rings ½–2
Press machine
a
min
[mm]
Type 2 (PT2)
20
Type PT3-EH
Type PT3-AH
Pressgun 4E / 4B
Pressgun 5
Picco / Pressgun Picco
20
NOTICE!
Leaky press connections due to pipes being too short!
If two press connectors are to be mounted onto a pipe
without an interval, the pipe must not be too short. If the
pipe is not inserted up to the prescribed insertion depth in
the press connector during pressing, the connection may
become leaky.
Distance to walls
Interval between the pressings
Handling
Megapress
24 from 32
Содержание Megapress