4000 Series GSM Audio Intercom - Technical Manual
4000 Series GSM Audio Intercom with Proximity
TERMINAL CONNECTIONS
Connection
Description
+
12-24V AC or DC power input
-
0V power input
C1
Relay 1 common connection
Relay contacts:
3A@24Vac/dc
NO1
Relay 1 normally open connection
NC1
Relay 1 normally closed connection
C2
Relay 2 common connection
NO2
Relay 2 normally open connection
NC2
Relay 2 normally closed connection
C3
Relay 3 common connection
NO3
Relay 3 normally open connection
NC3
Relay 3 common connection
SW1
Switched 0V input to trigger relay 1
SW2
Switched 0V input to trigger relay 2
TECHNICAL SPECIFICATION
Working Voltage
: 12V - 24Vac/dc +/- 10%
Current (standby)
: 20mA
Current (during operation)
: 70mA (max.)
Dry Contact Relay
: 3A @ 24Vac/dc (max.)
Working
Temp.
:
-10
+50
o
C
CONNECTING THE CODELOCK TO THE GSM INTERCOM
Follow the connections as shown in
Fig.14
when connecting the Art.4800M codelock to the Art.4810 GSM intercom.
*
2
*
1
*
3
Fig. 14
*1 -
Remember to set the Art.4800M relay time to a shorter time than that of the Art.4810 GSM intercom relay time.
*2 -
If connecting the Art.4810 GSM PRO intercom to a gate controller then please refer to page 20 for correct wiring configuration.
*3 -
Set the Art.4810 GSM intercom relay time to a shorter time than that of the Art.4800M relay time.
for fail safe lock wiring
move lock wire from
NO to NC and set MOV1
jumper to NC1 position