4000 Series GSM Audio Intercom - Technical Manual
4000 Series GSM Audio Intercom with Proximity
Re-programming the Codelock
If the Art.4800M codelock has been programmed with an existing access code and it needs to be changed then follow the flow
chart below to re-program a new acces code:
Re-enter the existing
engineer’s code again.
Then press
ENTER.
Enter a new access
code for the relay.
Then press
ENTER.
Enter a two digit relay time
from 00 - 99 seconds.
Then press
ENTER.
Enter the existing
engineer’s code.
Then press
ENTER.
More codes?
Repeat steps for a new
access code and time
for relay 2 and relay 3
Press
ENTER
twice to
exit programming
YES
NO
The red LED will illuminate to indicate that
the codelock is in programming mode*4.
Alternatively enter a new eningeer’s code (4 - 8 digits).
Relay access code (4 - 8 digits) that operates the door or gate*
5
2 digit relay time (01 - 99 seconds or 00 for latching).
The red LED will switch OFF to
indicate that the codelock has
exited programming mode.
Melody
Melody
Melody
Melody
Melody
Programming Notes
*4 -
If the red LED does not illuminate then the engineer’s code has been previously changed or is incorrect. To reset this code follow
the factory reset procedure below.
*5 -
On the first loop of the flow chart above the access code is for relay 1 on the second loop the access code is for relay 2 and on
the third loop the access code is for relay 3.
RESETTING THE ENGINEER’S CODE BACK TO FACTORY DEFAULT ‘111111’ (6x1)
1. Remove/disconnect the power from the Art.4800M codelock.
2. Press and hold down the ENTER button while the power is switched back onto the codelock.
3. Once power is restored to the codelock release the ENTER button.
4. The engineer’s code has been reset back to the factory default of ‘111111’ (6x1).
Engineer’s Code
Relay 1 Code
Relay 1 Time
Relay 2 Code
Relay 2 Time
Relay 3 Code
Relay 3 Time