background image

ENUK - V1.4 - 25/01/17 

32

4000 Series GSM Audio Intercom - Technical Manual

4000 Series GSM Audio Intercom with Proximity

Programming the GSM Intercom

PROGRAMMING THE GSM INTERCOM

Programming the GSM PRO intercom can be carried out in two ways, either by sending text (SMS) messages or by using the GSMSK 
PC software (ver 3.0.0.2 or later).

IMPORTANT NOTE:  When you are required to use  “  in a text message it is very important to use the correct symbol and not for 
example  ‘  (or two  ‘  single apostrophes side by side which you will see look the same but will be interpreted differently by the 
GSM PRO intercom panel).

PROGRAMMING BY TEXT MESSAGE

Programming by text message is a simple way to customise the settings of the GSM PRO intercom panel and add or delete telephone 
numbers. If you have a large number of buttons or telephone numbers to enter you may find programming easier with the GSMSK 
PC software. Simply send texts in the following format shown below to the telephone number of the SIM within the GSM PRO 
intercom panel:

<4 DIGIT CODE> <3 DIGIT FUNCTION CODE> <OPTIONAL DATA> <OPTIONAL ?>

4 DIGIT CODE

This code prevents unauthorised access to the programmable features of the system. The code 
must be four digits long but can be any combination using digits 0 – 9. The default code is 1111 
and will be used for all examples in this manual.

3 DIGIT FUNCTION CODE

The 3 digit function code identifies the programmable feature to be changed. The code must 
be in capital letters. The following table lists the available codes.

DESCRIPTION

CODE

EXAMPLE

SETTINGS

DEFAULT

PAGE

Store a primary telephone no.

STN

1111STNnnn”01912243174”

nnn = 001 - 050

n/a

33 - 34

Store divert 1 telephone no.

STD

1111STDnnn”01912241559”

nnn = 001 - 050

n/a

33 - 34

Store divert 2 telephone no.

STE

1111STEnnn”01912243678”

nnn = 001 - 050

n/a

33 - 34

Store divert 3 telephone no.

STF

1111STFnnn”01912245326”

nnn = 001 - 050

n/a

33 - 34

Store dial to open no.

STR

1111STRnnn”07771234567”

nnn = 000 - 999

n/a

34

Set call time

SPT

1111SPTnn

nn = 01 - 12

02 

(40s)

34

Set relay time

RLT

1111RLTnn

nn = 00 - 99

05 

(5s)

34

Set auxiliary AO1 output time

A1T

1111A1Tnn

nn = 00 - 99

05 

(5s)

35

Set auxiliary AO1 out mode

A1M

1111A1Mnn

nn = 00 - 05

01

35

Set auxiliary AO2 output time

A2T

1111A2Tnn

nn = 00 - 99

05 

(5s)

35

Keep connection facility

NOD

1111NODnn

nn = 01 - 99

(disabled)

35 - 36

Divert to next no. time

DIT

1111DITnn

nn = 01 - 99

15 

(15s)

36

Check GSM signal strength

SIG

1111SIG?

n/a

n/a

36

Check software version

VER

1111VER?

n/a

n/a

36

Dial a number

DLE

1111DLE”123”

n/a

n/a

36

Store SMS message for g-4

SMS

1111SMS”HouseAlarm”

n/a

AUX TRIG

36

Change 4 digit code

CDE

1111CDE1234

Any 4 digits

1111

37

Trigger the relay

RLY

1111RLY

n/a

n/a

37

Trigger the auxiliary output AO1

A1O

1111A1O

n/a

n/a

37

Trigger the auxiliary output AO2

A2O

1111A2O

n/a

n/a

37

Store balance check dial string

SDL

1111SDL”*#1345#”

n/a

n/a

37

Check credit balance

BAL

1111BAL?

n/a

n/a

37 - 38

Store master telephone no.

STM

1111STM”07771234567”

n/a

n/a

38

Latch the relay

RLA

1111RLA

n/a

n/a

38

Unlatch the relay

RUL

1111RUL

n/a

n/a

38

Latch the auxiliary AO1 output

A1L

1111A1L

n/a

n/a

38

Unlatch the auxiliary AO1 output

A1U

1111A1U

n/a

n/a

38

Latch the auxiliary AO2 output

A2L

1111A2L

n/a

n/a

38

Unlatch the auxiliary AO2 output

A2U

1111A2U

n/a

n/a

39

Содержание GSM4K Series

Страница 1: ...COM KIT 4000 Series GSM Audio Intercom with Proximity ENUK V1 4 25 01 17 We recommend This equipment is installed by a Competent Electrician Security or Communications Engineer Technical Manual Englis...

Страница 2: ...RF exposure requirements a separation distance of 20cm 7 87 or more must be maintained between the antenna of this product and all persons Separate FCC approval for this product is not required as it...

Страница 3: ...d Available Versions 7 Technical Information 13 Wiring Diagrams 19 Auxiliary Inputs Outputs 21 General Directions for Installation 25 Reset Procedure 29 4000 Series Back Box Installation 30 Programmin...

Страница 4: ...or gate relay without being charged for the call Programmable timeband facility Micro USB connection for ease of programming using the GSMSK PC software Integrated bootloader function for updating int...

Страница 5: ...num ber is located internally on the main hardware chip inside the GSM PRO module To gain access to the GSM module and obtain this number the module will have to be opened It is recommended that you c...

Страница 6: ...phone number in your own mobile phone avoid using an obvious name such as Front Door or My Gate as this would make it easy to decipher if your phone was lost or stolen The PIN request feature must be...

Страница 7: ...4810 1D Art 4810 2D Fig 2 EXTENSION BUTTON MODULES The GSM intercom module will accept up to 50 call buttons Any of the standard 4000 series button modules can be used as shown in Fig 3 along with the...

Страница 8: ...e GSM module has 4 buttons Art 4810 2D the additional button module buttons should be wired starting from button number 5 i e the first button of the button module should be connected between a 5 the...

Страница 9: ...0 x 143 x 46 Art 4852 2 135 x 280 2 x 15 7 120 x 263 2 x 46 Art 4853 3 135 x 400 4 x 15 7 120 x 383 4 x 46 Surface Back Boxes and Mounting Frames Art 4881 Art 4882 Art 4883 Art 4884 Art 4886 Art 4889...

Страница 10: ...or mounting 4 SMA male connector cablelength2 5m 5 Expansion type wall plugs 6mm 6 Self threading screw 4mmx30mm IMPORTANT NOTE An antenna must always be fitted for the GSM module to work Always route...

Страница 11: ...or station composed of 1Art 4810 2 2buttonGSM pro unit 1Art 4881 Surfacemountingbox 1 GSM antenna Art 432 1 Power supply Art 324 ONE WAY VERSIONS GSM4KC 1 flush mounting 1 Outdoor station composed of...

Страница 12: ...and appropriate surface back box depending on the GSM4K nS kit required where n the number of call buttons GSM4KC AUDIO KITS Additional GSM4KC n flush kit versions available from 3 way kits up to 12...

Страница 13: ...EPLATE ILLUMINATION JUMPER JP2 The nameplate LED illumination jumper JP2 is located behind the GSM module s front stainless steel facia as shown in Fig 11 To access the jumper the facia must be remove...

Страница 14: ...D illumination adjustment JP2 position A LED bright JP2 position B LED low JP2 removed LED disabled CALL PROGRESS LED S LED sign Description The busy LED when illuminated indicates that it is not poss...

Страница 15: ...t switched 0V 150mA max Dry Contact Relay 3A 24Vdc 3A 120Vac Event Log up to 4000 events USB Port micro USB Timebands 1 programmable timeband Working Temp 10 50o C ART 4800M CODELOCK MODULE Fig 12 REL...

Страница 16: ...to trigger relay 2 TECHNICAL SPECIFICATION Working Voltage 12V 24Vac dc 10 Current standby 20mA Current during operation 70mA max Dry Contact Relay 3A 24Vac dc max Working Temp 10 50o C CONNECTING THE...

Страница 17: ...TER Press ENTER twice to exit programming YES NO This new engineer s code can be from 4 8 digits long and will not activate the relays It can only be used to enter programming mode Please note that th...

Страница 18: ...operates the door or gate 5 2 digit relay time 01 99 seconds or 00 for latching The red LED will switch OFF to indicate that the codelock has exited programming mode Melody Melody Melody Melody Melody...

Страница 19: ...nections for a GSM4K 1 GSM4K 1S audio kit Fig 15 GSM4KC CONNECTIONS Fig 16 shows connections for a GSM4KC 1 GSM4KC 1S audio kit Fig 16 6 Set the Art 4810 GSM intercom relay time to a shorter time than...

Страница 20: ...d that the GSM relay is connected with the Art 120 opto isolator pcb provided with the GSM kit The gate controls can then be connected into the C and NO terminals on the Art 120 pcb Follow the connect...

Страница 21: ...s set to will determine how the AO1 output behaves The following examples show how the AO1 output can be connected AO1 SET TO MODE 00 CALL ACTIVATED When set to mode 00 auxiliary output AO1 will activ...

Страница 22: ...uired and the AO1 input must be wired as shown in Fig 21 Fig 21 AO1 SET TO MODE 03 DIVERT CALLS TO MASTER NUMBER It is possible to have all call buttons diverted to the master number outside certain h...

Страница 23: ...r to programming notes on page 35 or setup by using the GSMSK PC programming software Fig 23 AO1 SET TO MODE 05 ENABLE DISABLE DIAL TO OPEN NUMBERS When the auxiliary output AO1 mode is set to 05 the...

Страница 24: ...utput for the programmed A2T time 1111A2L to latch the AO2 output 1111A2U to unlatch the AO2 output For this feature an additional transistor switched device will be required Fig 25 below shows an exa...

Страница 25: ...n Do not obstruct the ventilation openings or slots on any of the devices All connections to mains voltages must be made to the current national standards I E E wiring regulations or the appropriate s...

Страница 26: ...pole circuit breaker refer to Fig 29 which shall have contact separation of at least 3mm in each pole and shall disconnect all poles simultaneously That the all pole circuit breaker shall be placed i...

Страница 27: ...h build up around the call buttons which may prevent the buttons from operating correctly FITTING A SIM CARD After connecting the power supply antenna lock output and any auxiliary devices as shown in...

Страница 28: ...tialise properly We recommend NOT sending SMS messages or pressing buttons during this time The busy LED will flash while initialising 8 From power up two short beeps will be heard and then following...

Страница 29: ...imity cards and settings RESETTING THE MASTER CODE TO 1111 4x1 1 Power down the intercom panel 2 Put a short across terminals g 7 3 Power up 2 beeps will be heard followed by a delay and then a furthe...

Страница 30: ...com with Proximity 4000 Series Back Box Installation EXAMPLE INSTALLING A 4000 SERIES FOUR MODULE BACK BOX Fig 38 Fig 39 Fig 40 Fig 41 Fig 42 Fig 43 Fig 44 Fig 45 Fig 46 Fig 47 Fig 48 Fig 49 Fig 50 Fi...

Страница 31: ...been tested and is working correctly move back the module support frames carefully fix them to the surface box using the screwdriver provided P torx end and the pin machine torx screws Q Fig 48 Note d...

Страница 32: ...ESCRIPTION CODE EXAMPLE SETTINGS DEFAULT PAGE Store a primary telephone no STN 1111STNnnn 01912243174 nnn 001 050 n a 33 34 Store divert 1 telephone no STD 1111STDnnn 01912241559 nnn 001 050 n a 33 34...

Страница 33: ...AL Mostofthecommandssupportthe feature Whenthisisaddedtotheendofthetextmessage a confirmation text message will be sent back to the sender indicating the new data has been received and stored When sen...

Страница 34: ...com when using this feature see the Forced Dial section for more details Also note that it will not be possible to use the dial in to speak facility from a number stored to release the door gate when...

Страница 35: ...l begins and deactivate when the auxiliary 1 output time A1T expires See example on page 23 Enable Disable Dial to Open nn 05 When in this mode the AO1 terminal is used to enable disable the dial to o...

Страница 36: ...ent version of software on the GSM PRO intercom This may be necessary to see if an update is required for any additional features or updates on the GSM PRO intercom which may be included on later vers...

Страница 37: ...11A2O Trigger auxiliary output AO2 for the programmed time 1111A2O Trigger auxiliary output AO2 for the programmed time and send a confirmation text back to the sender STORE BALANCE CHECK DIAL STRING...

Страница 38: ...connected to a gate controller and the user wishes to hold open the gate The following text message can be sent to the GSM PRO intercom 1111RLA Latch the GSM PRO relay to the C NO position 1111RLA Lat...

Страница 39: ...firmation text back to the sender with the stored setting 1111TBA Query time band setting A text message will be sent to the sender with the stored time window 1111TBA Delete the time band and allow c...

Страница 40: ...into a telephone system where an automated menu is present and a DTMF tone is required to select a particular option from the menu This feature is disabled by default The following programming text me...

Страница 41: ...CK PBY 02 03 04 This function of the built in proximity reader will only be applicable if the proximity reader has been enabled see EPR function above After the proximity reader is enabled the number...

Страница 42: ...site code Example 2 Programming a PBX1E or PBX2 with a 3 digit site code of 123 a 5 digit user code of 45678 and storing it in memory location 010 the following text can be sent to the GSM PRO interc...

Страница 43: ...1111FDF 12345 The GSM PRO intercom will reply with the following text STORED IN nnn OK VIDEX GSM where nnn the fob card location of where the fob card is stored DOOR OR GATE GAT This command feature...

Страница 44: ...This is an advanced feature of the system which can allow an AT format command to be sent to the OEM GSM module 1111PRG command Send an AT command to the OEM module AT COMMAND SEND AT START UP AT1 AT...

Страница 45: ...will also clear the call down Pressing the same button before the five seconds is up will do nothing Fig 56 Fig 57 Fig 58 Fig 59 DOOR GATE RELEASE This is signalled by 1 second interval beeps from th...

Страница 46: ...SM intercom while in standby the examples shown in the table use the default 4 digit master code 1111 FUNCTION MESSAGE TO SEND Check the signal strength 1111SIG Check the available balance 9 1111BAL C...

Страница 47: ...phone number of the telephone dialling in must be stored in memory location dial to open list STR000 STR999 1st Dial in to activate a call live speech activate relay auxiliary AO1 AO2 After dialling t...

Страница 48: ...umber stored This may be the required setup but if it s not then either change the time band times store a master number to divert the calls to or open the switch between AO1 g used to switch the call...

Страница 49: ...e No The table format below can be used to record the call button numbers and the three divert numbers from 001 to 050 BUTTON MEM LOCATION TELEPHONE NO USER NAME Button 1 STN001 Button 1 divert 1 STD0...

Страница 50: ...d into a mobile phone to check Contact the SIM card provider if you are not sure Check the number you are sending the message to is correct the number of the SIM card in the GSM PRO intercom panel Aft...

Страница 51: ...Update AT commands Included door gate setup GAT and shutdown and restart feature RBT User command to activate auxiliary output AO2 included FURTHER READING Additional programming information using the...

Страница 52: ...ENUK V1 4 25 01 17 52 4000 Series GSM Audio Intercom with Proximity 4000 Series GSM Audio Intercom Technical Manual Notes...

Страница 53: ...ENUK V1 4 25 01 17 53 4000 Series GSM Audio Intercom with Proximity 4000 Series GSM Audio Intercom Technical Manual Notes...

Страница 54: ...ENUK V1 4 25 01 17 54 4000 Series GSM Audio Intercom with Proximity 4000 Series GSM Audio Intercom Technical Manual Notes...

Страница 55: ...ENUK V1 4 25 01 17 55 4000 Series GSM Audio Intercom with Proximity 4000 Series GSM Audio Intercom Technical Manual...

Страница 56: ...olaou Str 11633 ATHENS Phone 30 210 7521028 30 210 7521998 Fax 30 210 7560712 www videx gr videx videx gr Danish office VIDEX DANMARK Hammershusgade 15 DK 2100 COPENHAGEN Phone 45 39 29 80 00 Fax 45 3...

Отзывы: