Speech Playback
In the top right corner of the ‘settings’ window is
the speech playback drop down menu with three
available options; None, Individual and Combined.
This setting is used to set the onboard speech
board in the 4212 digital panel. The default setting
is combined speech playback. By clicking on the
drop down menu button (
▼
) on the right of the field this setting can be changed
(if ‘none’ is selected
then there will be no speech playback when a call is made to the flat. If ‘individual’ is selected then the
speech annunciation will playback the individual numbers that make up the flat number e.g. if calling
flat 25 the speech will playback “calling two five”. If ‘combined’ is selected then the speech annunciation
will playback the combined flat number e.g. if calling flat number 15 the speech will playback “calling
fifteen”).
Door No.
Below the speech playback is the door number drop
down menu with up to 15 available door selections.
Use this menu to select and set the door number of
the 4212 digital panel
(this feature is used on video
systems where the camera recall function is required
or on systems including a 2210 concierge and a panel
recall is required).
Language
Below the door number setting is the language
selection with 6 languages available; English
(default)
, Italian, Spanish, Portugeuse, French and
German. Use this menu to set the display language
on the 4212 digital panel
(please note that this option
sets the display language on the 4212 digital panel
only and
not
the language of the PC programming
software).
Door Mode
Below the language setting is the door mode
selection. There are 2 door modes; LOCAL and MAIN.
(MAIN mode should only be used for 4212 panels that
call all users and on systems that include 2206N bus
exchange devices, LOCAL mode can be used for all
other applications. When using the 4212 panel in MAIN
mode, the programming of each user will require the address of the 2206N [block ID] for which that user
is connected. When this option is selected the block ID column on the ‘apartments’ tab will become
available to set the block ID. When in LOCAL mode the block ID column will not be available and will be
‘grayed out’. Also refer to block ID programming on page X).