Page 22 SW164OSM 9901
Alarm dwell times
From ALARM menu, press
3
to access ALARM DWELL
TIME submenu.
If multiple inputs are displayed on alarm, the dwell time of
each input is determined. The duration is between 1 and 60
seconds.
Select the video input whose time has to be modified by
pressing the relevant number (1/16).
Modify the duration by pressing
E
(one second increase)
and
C
(one second decrease).
M
copies the value of the first input to all the others.
P
confirms the modifications and returns to the previous
menu
TIME CYCLE 3.3
------------------------
1.02 9.01 Push 1/16
2.05 10.01 to select
>3.02< 11.01
4.01 12.01 ENT.Plus
5.01 13.01 CLR.Minus
6.01 14.01
7.01 15.01 M/A.Copy
8.01 16.01 first
------------------------
PROG.End
Reset of alarm condition
From ALARM menu, press
4
to access the ALARM RESET submenu.
Enable or disable each type of reset pressing
1
,
2
and
3
.
If TIME AUTO RESET is enabled, the keys
U
and
D
are used to select the
time, from 5 seconds to 1 hour after the last alarm signal.
P
confirms the modifications and returns to the previous menu.
ALARM RESET 3.4
------------------------
1. Keyboard : YES
2. External : NO
3. Auto reset : YES
after 20 sec.
áâ
to change delay
------------------------
PROG.End
Alarm recognition
From ALARM menu, press
5
to access the ACKNOWLEDGEMENT submenu.
Each output can be set in order to acknowledge only a group of alarm contacts.
This allows the alarm to be displayed on only one monitor, while the others
perform their normal sequences.
Select each of the 4 outputs, and proceed with the configuration.
ACKNOWLEDGEMENT 3.5
------------------------
1. Output no.1
2. Output no.2
3. Output no.3
4. Output no.4
------------------------
PROG.End
In the shown example, the output number 3 recognises only the alarm conditions
on contacts 1, 2 and 4. Any alarm on these contacts generates a sequence cycle
(on the output 3) with the corresponding alarm groups. Any alarm condition on
the other contacts is ignored.
Press the corresponding number (1/16) to enable (
X
) or disable (
-
) the
acknowledgement of a contact.
E
enables the recognition of all contacts;
C
disables it.
P
confirms the modifications and returns to the preceding menu.
ACKNOWLEDGEMENT 3.53
------------------------
OUTPUT NO.3
1.X 9.- Push 1/16
2.X 10.- to toggle
3.- 11.-
4.X 12.- ENTER.All ON
5.- 13.- CLEAR.All OFF
6.- 14.-
7.- 15.-
8.- 16.- PROG.End
Dwell time
Input to be set
Содержание SW164OSM
Страница 2: ......
Страница 3: ......
Страница 4: ...MANUALE D USO ...
Страница 37: ...OPERATING INSTRUCTIONS ...
Страница 70: ...MANUEL D INSTRUCTIONS ...
Страница 103: ...BEDIENUNGSANWEISUNG ...