5. Operation
5.1. Check Points before Operation
Before power is applied, please check the cables carefully.
The camera ID of the controller must be identical to that of the target camera. The camera
ID can be checked by reading the DIP switches of the camera.
If your controller supports multi-protocols, the protocol must be changed to match to that of
the camera.
If you changed any camera protocol via DIP switches, the change will not be effective until
after you reboot the camera.
Since the operation method can be different for each controller available, refer to the
manual (INS-60ZRC200) for your controller. The operation of this manual is based on the
standard Pelco Controller.
5.2. Preset and Pattern Function Pre-Check
Check how to operate the preset and pattern functions with the controller or DVR in
advance to operate the camera functions fully when using the controller or DVR.
Refer to the following table when using a standard Pelco protocol controller.
< Go Preset >
Input [Preset Number] and press [Preset] button shortly.
< Set Preset > Input [Preset Number] and press [Preset] button for more than 2 seconds.
< Run Pattern> Input [Pattern Number] and press [Pattern] button shortly.
< Set Pattern > Input [Pattern Number] and press [Pattern] button for more than 2 seconds.
If the controller or DVR has no pattern button or function, use shortcut keys with preset
numbers. For more information, refer to "Reserved Preset" (Section 4.4) in this manual.
5.3. Starting OSD Menu
Function: Using the OSD menu; Preset, Pattern, Swing, Group and Alarm I/O function can
be configured for each application.
Enter Menu: <Go Preset> [95]