4.2. Address ID Setup
The ID number of the camera is set using a binary number. An example is shown below.
The range of IDs are 1~255. Do not use 0 as camera ID. The factory default of the
camera ID is 1.
To control a certain camera, you must match the camera ID with the Cam ID setting of the
DVR or Controller.
4.3. Options
When a sensor input is used, its functional type should be set.
There are two types; Normally Open type and Normally Closed type.
- Normal Open: Voltage is let out when the sensor is activated
- Normal Close: Voltage is let out when the sensor is not activated
Pin
Switch position
Sensor type
ON
Sensor 1 Normal Close
ST0 (Pin 4)
OFF
Sensor 1 Normal Open
ON
Sensor 2 Normal Close
ST1 (Pin 5)
OFF
Sensor 2 Normal Open
ON
Sensor 3 Normal Close
ST2 (Pin 6)
OFF
Sensor 3 Normal Open
ON
Sensor 4 Normal Close
ST3 (Pin 7)
OFF
Sensor 4 Normal Open
Termination (switch 8): to be used for RS485 wiring to provide noise immunity. In multiple
camera chain, termination should be on the last camera. Default is ON.