Communication Protocol Setup
1
2
3
4
ON
ON
Reserved for Supplier
RS-485 Termination Resistor
Select the appropriate Protocol with DIP switch combination.
Switch State
P0
(Pin 1)
P1
(Pin 2)
Protocol
OFF
OFF
PELCO-D, 2400 bps
ON
OFF
PELCO-D, 9600 bps
OFF
ON
PELCO-P, 4800 bps
ON
ON
PELCO-P, 9600 bps
If you want to control using DVR or P/T controller, their protocol must
be identical to camera. Otherwise, you can not control the camera.
If you changed camera protocol by changing DIP S/W, the change
will be effective after you reboot the camera.
Factory default of protocol is “Pelco-D, 2400 bps”.
Since Pin 3 is only for supplier, DO NOT CHANGE THESE ITS
ORIGINAL STATE
.
If you change one of these, proper operation can
not be achieved.
Pin 3
PAL / NTSC system selection of Camera. DO NOT
CHANGE THIS PIN.
INSTALLATION
2
Pin 4 is used for ON/OFF of RS-485 Termination. Normally, it must be
OFF state. Especially when you have trouble with long Daisy chain
style connection, turn ON this termination switch of last camera.
Pin 4
RS-485 Termination Resistor (On/Off)