2.3.7 Special Settings (default: on)
2.3.7.1 Bulk Protection On/ Off
If the charger has not reached the absorption voltage after 10 hours' charging in the bulk
phase, the battery may be defective. In order to prevent further damage, the charger will
automatically cut out after 10 hours' bulk. The “bulk” LED will start to flash.
This safety cut out can be switched off.
Set the DS 3-7
Switch the bulk cut-out to on or off
Example
DS-8
DS-7
off
DS-6 on
DS-5
off
DS-4 on
DS-3
off
DS-2
DS-1
Determine whether the bulk cut out
should be switched on or off.
The default is On.
The left-hand LED column is for On.
The right-hand LED column is for
Off.
Press the pushbuttons until the
required LED indication is
displayed.
Required: bulk cut out is off.
LED indication =
On
Off
2.3.7.2 AC Waveform Check (default: on)
The Phoenix Multi checks if the mains voltage has not only the correct voltage, but also the
correct shape
. When the Phoenix Multi does not function properly on a generator this
function can be disabled.
Set the DS 3-7
Switch the Mains Voltage Check to
on or off
Example
DS-8
DS-7
off
DS-6 on
DS-5
off
DS-4
off
DS-3 on
DS-2
DS-1
Determine whether the Mains
Waveform Check should be
switched on or off.
The default is On.
The left-hand LED column is for On.
The right-hand LED column is for
Off.
Press the pushbuttons until the
required LED indication is
displayed.
Required: Mains Waveform
Check is off.
LED indication =
On
Off