10
2.3.5 Inverter Settings
Inverter Voltage (default: 230 V)
The inverter voltage can be set between 180Vac-245Vac.
Set the DS 3-7
Specify the voltage
Example
DS-8
DS-7 on
DS-6 on
DS-5
off
DS-4
off
DS-3
off
DS-2
DS-1
Specify the required voltage Vq.
Determine the setting number:
scale=1V
offset=180V setting
number=(Vq-180)
Determine the LED indication.
Press the pushbuttons until the
required LED indication is
displayed.
Required: voltage is 225V.
Setting number = 225-180 = 45.
LED indication =
0
0
0
1
2
2
2
2
4
5
Increment size is 1V.
NOTE:
for setting the voltage of the Phoenix Inverter a voltage meter is to be used, because
the Phoenix Inverter has only 4 LEDs.