8 manual
victron energy
1.3 Battery requirements
For correct operation, the battery voltage should be between
0.92xVnom and 1.23xVnom where Vnom is 12V, 24V or 48V
depending on the model, and must be able to supply sufficient current to
your inverter. The following table displays the recommended battery
capacity per inverter type :
Inverter type :
Iin at Pnom :
Recommended battery
capacity:
Ph 12/220
18 Adc
≥
50Ah
Ph 24/220
9 Adc
≥
30Ah
Ph 48/220
4 Adc
≥
20Ah
Ph 12/300
26 Adc
≥
100Ah
Ph 24/350
15 Adc
≥
60Ah
Ph 12/600
47 Adc
≥
200Ah
Ph 24/800
29 Adc
≥
120Ah
Ph 48/800
14 Adc
≥
60Ah
The inverter shuts down when the battery voltage is below approx.
0.88xVnom or above 1.3xVnom. In a low or high battery situation the
inverter generates one beep per second (except Phxx/220 models).
CAUTION
THE Ph 12/220, Ph 12/300 AND Ph 12/600
MUST BE CONNECTED ONLY TO A 12V
BATTERY.
The inverter will not operate from
a 6V battery. The inverter will be damaged
when the battery voltage is higher than 24V.
THE Ph 24/220, Ph 24/350 AND Ph 24/800
MUST BE CONNECTED ONLY TO A 24V
BATTERY.
The inverter will not operate from
a 12V battery. The inverter may be damaged
when the battery voltage is higher than 31V.
THE Ph 48/220 AND Ph 48/800 MUST BE
CONNECTED ONLY TO A 48V
BATTERY.
The inverter will not operate from
a < 40V battery. The inverter may be damaged
when the battery voltage is higher than 60V.