6 manual
victron energy
1. INSTALLATION
1.1 Location of the inverter
1 Ceiling
mounting
(inverted).
Not recommended
2. Base
mounting.
OK
3 Vertical
wall
mounting,
fan at bottom.
OK
(beware of small objects falling
through the ventilation openings on
top).
4 Vertical
wall
mounting,
fan on top.
Not recommended
5 Horizontal
wall
mounting.
OK
For best operating results, the inverter should be placed on a flat
surface. To ensure a trouble free operation of the inverter, it must be
used in locations that meet the following requirements:
a)
Avoid any contact with water. Do not expose the inverter to rain or
moisture.
b)
Do not place the unit in direct sunlight. Ambient air temperature
should be between 0
°
C and 40
°
C (humidity < 95% non
condensing). Note that in extreme situations the inverter’s case
temperature can exceed 70
°
C.
c)
Do not obstruct the airflow around the inverter. Leave at least 10
centimetres clearance around the inverter. When the inverter is
running too hot, it will shut down. When the inverter has reached a
safe temperature level the unit will automatically restart again.