manual
19
victron energy
3.3 Phoenix 12/600, 24/800 and 48/800
TECHNICAL DATA
Ph 12/600
Ph 24/800
Ph 48/800
Cont. output at 25°C
4)
600VA
800VA
800VA
Cont. output power at 25°C
1)
480W 600W 600W
Cont. output power at 40°C
1)
430W 540W 540W
Peak power
1000W
1200W
1250W
Output voltage
230Vac
±
2% or 115Vac
±
2%
Output frequency
50Hz
±
0.05% or 60Hz
±
0.05%
Output waveform
True sinewave
Total harmonic distortion
Maximum 5%
3)
Admissible cos
ϕ
of load
0.2 – 1
Input voltage (±3% tol.):
Nominal 12Vdc
24Vdc
48Vdc
Range 10.5
2)
– 16Vdc 21
2)
– 31Vdc 41
2)
– 60Vdc
Maximum efficiency
92%
94%
94%
No load power consumption at
nominal input voltage
[economy]
< 4.8W
[0.4W]
< 6.5W
[0.7W]
< 8.2W
[0.5W]
Operating temperature range
(ambient)
-20
°
C to +50
°
C
Economy threshold
Pout = 15W
Pout = 15W
Pout = 15W
Protections against
Short circuit, overload, high temperature and
high/low battery voltage
Indications (by pre-
programmed flashing
sequences of the power LED)
Power on, short circuit/overload, high
temperature, high/low battery voltage and
economy mode
DC input connection
Two wires, length 1.5 meters,
∅
10mm²
AC output connection
IEC-320 AC outlet
Enclosure body size
(l x h x w)
228 x 113 x 163 (without mounting brackets)
Protection class
IP20
Total weight
6.2 kg
6.2 kg
6.2 kg
The inverter complies with the
following standards :
EN50081-1 Generic Emissions Standard
EN50082-1 Generic Immunity Standard
EN60335-2 Safety Standard
1)
Measured with resistive load. Power ratings are subject to a
tolerance of ± 4%.
2)
Undervoltage limit is dynamic. This limit decreases with increasing
load to compensate the voltage drop across cables and connections.