5
E
N
A
p
p
e
n
d
ix
Two outputs to charge 2 battery banks
The MultiPlus features two outputs, of which one can carry the full output current.
The second output, limited to approximately 4 A and with a slightly lower output
voltage, is intended to top up a starter battery.
To increase battery life: temperature compensation
Every MultiPlus comes with a battery temperature sensor. When connected, charge
voltage will automatically decrease with increasing battery temperature. This
feature is especially recommended for sealed batteries and/or when important
fluctuations of battery temperature are expected.
Battery voltage sense
In order to compensate for voltage loss due to cable resistance the MultiPlus is
provided with a voltage sense facility so that the battery always receives the correct
charge voltage.
Learn more about batteries and battery charging
To learn more about batteries and charging batteries, please refer to our book ‘Energy
Unlimited’ (available free of charge from Victron Energy and downloadable from
www.victronenergy.com). For more information about adaptive charging please look
under Technical Information on our website.
Содержание MultiPlus 12/3000/120 - 50
Страница 1: ...Manual EN Appendix MultiPlus 12 3000 120 50 120V 24 3000 70 50 120V ...
Страница 2: ......
Страница 4: ......
Страница 50: ......
Страница 51: ...EN Appendix www victronenergy com APPENDIX A Overview connections B H I J F E G A C K L ...
Страница 53: ...EN Appendix www victronenergy com APPENDIX B Block diagram See table in section 4 2 ...
Страница 58: ...APPENDIX G Dimensions ...
Страница 59: ...EN Appendix www victronenergy com ...
Страница 60: ......
Страница 61: ...www victronenergy com ...