7.3.2 VE.Bus error codes
A VE.Bus system can display various error codes. These codes are displayed with the
"inverter on", "bulk", "absorption" and "float" LEDs.
To interpret a VE.Bus error code correctly, the following procedure should be
followed:
1. Is the "inverter on" LED flashing? If not, then there is
no
VE.Bus error code.
2. If one or more of the LEDs "bulk", "absorption" or "float" flashes, then this flash
must be in phase opposition to the "inverter on" LED, i.e. the flashing LEDs are off if
the "inverter on" LED is on, and vice versa. If this is not the case, then there is
no
VE.Bus error code.
3. Check the "bulk" LED, and determine which of the three tables below should be
used.
4. Select the correct column and row (depending on the "absorption" and "float"
LEDs), and determine the error code.
5. Determine the meaning of the code in the tables below.
Bulk LED off
Absorption LED
off
Flashing
on
F
lo
a
t
L
E
D
off
0
3
6
flashing
1
4
7
on
2
5
8
Bulk LED flashes
Absorption LED
off
Flashing
on
F
lo
a
t
L
E
D
off
9
12
15
flashing
10
13
16
on
11
14
17
Bulk LED on
Absorption LED
off
Flashing
on
F
lo
a
t
L
E
D
off
18
21
24
flashing
19
22
25
on
20
23
26
Содержание MultiPlus 12/3000/120 - 50
Страница 1: ...Manual EN Appendix MultiPlus 12 3000 120 50 120V 24 3000 70 50 120V ...
Страница 2: ......
Страница 4: ......
Страница 50: ......
Страница 51: ...EN Appendix www victronenergy com APPENDIX A Overview connections B H I J F E G A C K L ...
Страница 53: ...EN Appendix www victronenergy com APPENDIX B Block diagram See table in section 4 2 ...
Страница 58: ...APPENDIX G Dimensions ...
Страница 59: ...EN Appendix www victronenergy com ...
Страница 60: ......
Страница 61: ...www victronenergy com ...