5.5 Configuration with DIP switches
A number of settings can be changed using DIP switches (see appendix A, position
M).
This is done as follows:
Turn the MultiPlus on, preferably without load en without AC voltage on the input. The
MultiPlus will then operate in inverter mode.
Step 1:
Setting the DIP switches for:
- the required current limitation of the AC input.
- AES (Automatic Economy Switch)
- maximum charge current.
- selection of stand-alone, parallel or 3-phase operation.
To store the settings after the required values have been set: press the 'Up' button for
2 seconds (
upper
button to the right of the DIP switches, see appendix A, position J).
The DIP switches can now be used to apply the remaining settings (step 2).
Step 2:
other settings
To store the settings after the required values have been set: press the 'Down' button
for 2 seconds (lower button to the right of the DIP switches). The DIP switches can be
left in the selected positions, so that the ’other settings’ can always be recovered.
Remarks:
- The DIP switch functions are described in 'top to bottom' order. Since the uppermost
DIP switch has the highest number (8), descriptions start with the switch numbered 8.
- In parallel mode or 3-phase mode, not all devices require all settings to be made
(see section 5.5.1.4).
For parallel or 3-phase mode, read the whole setting procedure and make a note of
the required DIP switch settings before actually implementing them.
Содержание MultiPlus 12/3000/120 - 50
Страница 1: ...Manual EN Appendix MultiPlus 12 3000 120 50 120V 24 3000 70 50 120V ...
Страница 2: ......
Страница 4: ......
Страница 50: ......
Страница 51: ...EN Appendix www victronenergy com APPENDIX A Overview connections B H I J F E G A C K L ...
Страница 53: ...EN Appendix www victronenergy com APPENDIX B Block diagram See table in section 4 2 ...
Страница 58: ...APPENDIX G Dimensions ...
Страница 59: ...EN Appendix www victronenergy com ...
Страница 60: ......
Страница 61: ...www victronenergy com ...