4. System Design considerations and examples
4.1. Integration into the Lynx Distributor System
The Lynx Smart BMS integrates seamlessly with the
system, which is not mandatory for operation, but highly
recommended due to its ease of installation.
It is important to note that the battery must always be connected to the left side of the Lynx Smart BMS (in normal position), while
all loads and chargers are connected to the right side.
The example below shows the Lynx Smart BMS in a system with two Lynx Distributors. Together they form a continuous busbar
with fused battery connections, battery monitor, BMS system, contactor and fused load connections.
The Lynx modules can be mounted in any orientation. Should they be mounted upside down, so that the text on the front of the
units is upside down as well, use the special stickers are included with each Lynx module, so that the text is orientated the correct
way.
Fused battery connections
Fused DC loads and charge connections
Battery monitor, BMS and contactor
Lynx Smart BMS with two Lynx Distributors
From battery bank
To DC system,
All DC loads and DC charge
sources
Example of Lynx module orientation: the batteries connect to the left and all loads and chargers connect on the right side
From battery bank
To DC system,
All DC loads and DC charge
sources
Example of Lynx modules mounted upside down: now the batteries connect to the right side, all loads and chargers connect to
the left side and the upside down stickers (included) are affixed.
It is important to note that the battery is always connected to the left side of the Lynx Smart BMS (in normal
position), while all loads and chargers go to the right side.