background image

User Manual for RIS Refrigerators 

Victory

Rev. 10/20

Victory

21

Cleaning Needed

Cleaning Agent

Method of Application

Affect on Finish

Smears and fingerprints

Areal 20, Lac-O-Nu, Lumin Wash
O’Cedar Cream Polish, Stainless 
Shine.

Rub with cloth as directed
on the package.

Satisfactory for use on all 
finishes.
Provides barrier film to 
minimize prints.

Stubborn Spots and
Stains, Baked-On
Splatter, and Other
Light Discolorations

Allchem Concentrated Cleaner.

Apply with damp sponge or 
cloth.
Rub with damp cloth.

Use in direction of polish lines 
on No. 4 (polished) finish. May 
scratch No.
2 (mill) and Nos. 7 and 8 
(polished) finishes.

Samae, Twinkle or Cameo Copper 
Cleaner

Rub with damp cloth.

Grade FFF Italian pumice, whiting, 
or talc.

Rub with dry cloth.

Liquid NuSteel
Paste NuSteel or DuBois Temp.
Copper’s Stainless Steel Cleaner
Revere Stainless Cleaner
Household cleansers, such as
Old Dutch, Lighthouse, Sunbrite,
Wyandotte, Bab-O, Gold Dust,
Sapolio, Bon Ami, Ajax, or Comet
Grade F Italian Pumice, Steel
Bright, Lumin Cleaner, Zud,
Restore, Sta-Clean, or Highlite.
Penny-Brite or Copper-Brite.

Use small amount of cleaner.
Rub with dry cloth using a 
small amount of cleaner.
Apply with damp sponge or 
cloth.
Rub with a damp cloth. May 
contain chlorine bleaches. 
Rinse
thoroughly after use.
Rub with a damp cloth.
Rub with a dry cloth using a 
small amount of cleaner.

Heat tint or
discoloration

Penny-Brite or Copper-Brite.
Past NuSteel, DuBois Temp,
or Tarnite. Revere Stainless Steel 
Cleaner. Allen Polish, Steel Bright, 
Tenacious Deposits,
Rusty Discolorations,
Industrial
Atmospheric Stains Wyandotte, 
Bab-O or Zud.

Rub with a dry cloth.
Rub with a dry cloth or stain-
less steel wool.
Apply with damp sponge or 
cloth.
Rub with a damp cloth.

Burnt-On Foods and
Grease Fatty Acids,
Milkstone (where
swabbing or rubbing
is not practical)

Easy-Off, De-Grease-It, 4 to 6% 
hot solution of such agents as 
trisodium phosphate or sodium 
tripolyphosphate or 5 to 15% caustic 
soda solution

Apply generous coating. Allow 
to stand for 10-15 minutes. 
Rinse.
Repeated application may be 
necessary.

Excellent removal, satisfactory 
for use on all finishes.

Tenacious Deposits,
Rusty Discolorations,
Industrial
Atmospheric Stains

Oakite No. 33, Dilac Texo 12, Texo NY, 
Flash-Klenz, Caddy Cleaner,
Turco Scale 4368 or Permag 57.

Swab and soak with clean 
cloth.
Let stand 15 minutes or more 
according to directions on 
package, then rinse and dry.

Satisfactory for use on all 
finishes

Hard Water Spots
and Scale

Vinegar.
5% oxalic acid, 5% sulfamic acid, 5 to 
10% phosphoric acid, or Dilac, Oakite 
No. 33, Texo 12, Texo N.Y.

Swab or wipe with cloth. Rinse 
with water and dry.
Swab or soak with cloth. Let 
stand 10-15 minutes. Always 
follow with neutralizer rinse, 
and dry.

Satisfactory for all finishes.
Satisfactory for all finishes. 
Effective on tenacious deposits 
or where scale
has built up.

METHODS FOR CLEANING  STAINLESS STEEL

Содержание RIS-1D-S1-PT-HC

Страница 1: ...STRUCTIONS for all Hydrocarbon RIS Refrigerator Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web victoryrefrigeration com 809 192A Rev B 10 29 2020 SEE BACK COV...

Страница 2: ...it or void the warranty Victory reserves the right to change specifications and product design without notice Such revisions do not entitle the buyer to corresponding changes improvements additions or...

Страница 3: ...gers There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other fl...

Страница 4: ...necessary to move the Refrigerator after removal from the skid remove all doors and carefully push the unit at a point of no more than 36 from the bottom to avoid damage CAUTION SAFETY Push ONLY below...

Страница 5: ...substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overheated or subjected to excessive cold May only be conn...

Страница 6: ...36 5 8 x 90 Full Solid 8 5 R 290 130 4 59 RIS A 2D S1 PT XH HC 38 3 4 x 40 x 90 Full Solid 8 5 R 290 130 4 59 RIS A 3D S1 HC 101 1 4 x 36 3 8 x 84 3 8 3 Full Solid 10 8 R 290 150 5 29 RIS A 3D S1 PT...

Страница 7: ...t side 0 0 in at the right side Floor Load The floor on which the Refrigerator is located must be even and level free from vibrations and strong enough to support the combined weights of the unit and...

Страница 8: ...on and discard 3 Move unit as close to final position as possible before removing the skid Do NOT tip unit on its front or sides If tipped onto the back unit must not be started for 3 hours Note addit...

Страница 9: ...ention bar facing up Be careful not to dislodge clips during installation 6 Place shelves so that the retaining tab on the clip captures the shelf as shown 7 Confirm that the shelf is resting on ALL 4...

Страница 10: ...plug If the power cord becomes damaged it must be replaced with the identical cord Follow All National and Local Codes This unit must be grounded Do not use extension cords and do not disable or by p...

Страница 11: ...he system to lower the temperature faster When on the refrigeration system is always operating at maximum The temperature was set at the factory at 38 F but you can adjust it to your own selected temp...

Страница 12: ...pressor is not running The Condenser Fan is wired directly to the Compressor not through the controller EVAPORATOR FAN The Evaporator Fan runs continuously When the unit is plugged in and the evaporat...

Страница 13: ...On Defrost active Blinking Activated manually or from Digital input OFF Otherwise 3 Fans Permanently On Fans active OFF Otherwise 4 Reduced SET Economy Permanently On Energy saving active Blinking Re...

Страница 14: ...16 17 LIGHT STANDBY UP DOWN ESC SET Enter Press and Hold Press and Hold Press and Release Press and Release Press and Release Press and Release Long press 5 sec Toggles light on and off If LED is on l...

Страница 15: ...ey pad will beep when unlocked and normal key pad operations performed Setting the Operating Set Point To change the operating set point press and release the set button to enter the machine menu set...

Страница 16: ...ss the set button to display the value and use the up or down button to change the value Once the value has been selected use the escape button to confirm the new value and return the pervious menu le...

Страница 17: ...User Manual for RIS Refrigerators Victory Rev 10 20 Victory 17...

Страница 18: ...P1 Att Afd HA1 PAO dAO OAO tA1 AH2 HIGH temperature 2 alarm ON Active Automatic SP2 Att Afd HA2 PAO dAO OAO tA2 AL2 LOW temperature 2 alarm ON Active Automatic SP2 Att Afd HA2 PAO dAO OAO tA2 EA Exter...

Страница 19: ...Rinse with clean water 3 Dry with a soft cloth 4 Polish with a soft cloth wiping with the grain 5 Wipe weekly with stainless steel cleaner Weekly Interior Cleaning 1 Remove all food food related item...

Страница 20: ...ip and secure into the notch in the front right corner of the raised panel 5 Examine condenser surface if dusty brush and vacuum the dust and lint from the surface of the coil Brush up and down to avo...

Страница 21: ...amount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Discolora...

Страница 22: ...ontrol No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage correct as needed Check start relay and start capacitor See next step No cooli...

Страница 23: ...ng MUST be in an area free from flame or spark It must be near an opened window or door A sign noting service of a system containing propane must be attached to the unit during refrigeration service A...

Страница 24: ...OT ALL MODELS 115VAC 60 HZ EVAP FAN BLU FAN RELAY 4 5 WHT CONTROL CIRCUIT 1 3 COMP RELAY 10 11 BRN WHT WHT BLK BLK WHT FASCIA HEATERS RED LIGHT RELAY 13 14 RED CABINET LIGHTS POWER SUPPLY BLACK WHITE...

Страница 25: ...in the Owner s Manual adjustment of door mechanisms or freight damage are not covered by this warranty For the purpose of this warranty the original purchaser shall be deemed to mean the individual or...

Страница 26: ...N LIEU OF ALL OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE HEREBY DISCLAIMED AND ALL OTHER OBLIGATIO...

Страница 27: ...___________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name _______________________________________________...

Отзывы: