background image

User Manual for RIS Refrigerators 

Victory

Rev. 10/20

Victory

25

LIMITED WARRANTY

WARRANTY (Continental USA & Canada Only)

THREE (3) YEAR PARTS & LABOR LIMITED WARRANTY

Victory® Refrigeration (Victory) warrants to the 
original purchaser of Victory branded equipment, that 
such equipment is free from defects in material and 
workmanship, under normal use, proper maintenance and 
service as indicated by Victory’s installation and operation 
instructions, for a period of three (3) years from the date 
of installation, or thirty-nine (39) months from the date of 
shipment from the manufacturer, whichever is earlier.

ADDITIONAL FOUR (4) YEAR COMPRESSOR PART LIMITED 
WARRANTY*

In addition to the warranty set forth above Victory® 
Refrigeration (Victory), warrants the hermetically/semi-
hermetically sealed compressor (part only) for an additional 
four (4) years beyond the initial three (3) year warranty 
period; not to exceed eighty-seven (87) months from the 
date of shipment from Victory, provided upon receipt of the 
compressor, manufacturer examination shows the sealed 
compressor to be defective. This extended warranty does 
not cover freight for the replacement compressor or freight 
for return of the failed compressor. Also, this extended 
compressor-part only warranty does NOT apply to any 
electrical controls, condenser, evaporator, fan motors, 
overload switch, starting relay, capacitors, temperature 
control, filter/drier, accumulator, refrigeration tubing, wiring 
harness, labor charges, or supplies which are covered by 
the standard warranty above.

*Units shipped after 03/01/2020.  Previous warranty 
applies to units shipped prior.   

Exceptions:

• 

Warranty does not apply for units installed in a 
Residential application.  Units are intended for 
Commercial use only.   

• 

Blast Chillers carry a 3 year parts and labor warranty; 2 
additional years for the compressor

Normal wear type parts, such as light bulbs/lamps, gaskets, 
fuses, batteries, blast chiller/freeze probes, thermostator 
electronic controller calibration and/ or adjustment, and 
any normal maintenance items as outlined in the Owner’s 

Manual, adjustment of door mechanisms or freight damage 
are not covered by this warranty. For the purpose of this 
warranty, the original purchaser shall be deemed to mean 
the individual or company for whom the product was 
originally installed. 

Proof of purchase must be supplied to Victory to validate 
the warranty. This warranty is valid only if equipment is 
properly installed, and started-up as outlined in the Owner’s 
Manual. 

 Removal or alteration of the serial/ data plate from 
equipment shall be deemed to release the Victory from all 
warranty obligations or any other obligations, expressed or 
implied .The warranty does not cover installation, start-
up, normal maintenance, food loss, or other consequential 
damage, and it excludes components that are removable 
without tools. Our obligation under this warranty shall be 
limited to repairing or replacing, including labor, any part of 
such product, which proves defective.

                                                                                                                                   
Victory reserves the right to examine any product 
claimed to be defective. The labor warranty shall be for 
self-contained units only and for standard straight time, 
which is defined as normal service rate time, for service 
performed during normal working hours. Any service 
requested outside of a servicer’s normal working hours will 
be covered under this warranty at the normal rate and any 
additional overtime rate will be the responsibility of the 
equipment purchaser. Victory shall not be responsible for 
any costs incurred if the work is performed by other than 
Victory’s authorized service personnel. Reimbursement 
claims for parts and/or labor service costs must be made 
in writing. Model, cabinet serial number and installation 
location must be shown on the claim. A receipted bill from 
the servicing agency must accompany the claim, together 
with full details of the service problems, diagnosis and 
work performed. Victory reserves sole discretion whether 
further documentation on a claim is   to be submitted. Any 
part determined to be defective in the product should be 
returned to the company within thirty (30) days under 
the terms of this warranty and must be accompanied by a 
record of the cabinet model, serial number, with a return 
material authorization number (RMA#) issued by the 
Victory.

Содержание RIS-1D-S1-PT-HC

Страница 1: ...STRUCTIONS for all Hydrocarbon RIS Refrigerator Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web victoryrefrigeration com 809 192A Rev B 10 29 2020 SEE BACK COV...

Страница 2: ...it or void the warranty Victory reserves the right to change specifications and product design without notice Such revisions do not entitle the buyer to corresponding changes improvements additions or...

Страница 3: ...gers There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other fl...

Страница 4: ...necessary to move the Refrigerator after removal from the skid remove all doors and carefully push the unit at a point of no more than 36 from the bottom to avoid damage CAUTION SAFETY Push ONLY below...

Страница 5: ...substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overheated or subjected to excessive cold May only be conn...

Страница 6: ...36 5 8 x 90 Full Solid 8 5 R 290 130 4 59 RIS A 2D S1 PT XH HC 38 3 4 x 40 x 90 Full Solid 8 5 R 290 130 4 59 RIS A 3D S1 HC 101 1 4 x 36 3 8 x 84 3 8 3 Full Solid 10 8 R 290 150 5 29 RIS A 3D S1 PT...

Страница 7: ...t side 0 0 in at the right side Floor Load The floor on which the Refrigerator is located must be even and level free from vibrations and strong enough to support the combined weights of the unit and...

Страница 8: ...on and discard 3 Move unit as close to final position as possible before removing the skid Do NOT tip unit on its front or sides If tipped onto the back unit must not be started for 3 hours Note addit...

Страница 9: ...ention bar facing up Be careful not to dislodge clips during installation 6 Place shelves so that the retaining tab on the clip captures the shelf as shown 7 Confirm that the shelf is resting on ALL 4...

Страница 10: ...plug If the power cord becomes damaged it must be replaced with the identical cord Follow All National and Local Codes This unit must be grounded Do not use extension cords and do not disable or by p...

Страница 11: ...he system to lower the temperature faster When on the refrigeration system is always operating at maximum The temperature was set at the factory at 38 F but you can adjust it to your own selected temp...

Страница 12: ...pressor is not running The Condenser Fan is wired directly to the Compressor not through the controller EVAPORATOR FAN The Evaporator Fan runs continuously When the unit is plugged in and the evaporat...

Страница 13: ...On Defrost active Blinking Activated manually or from Digital input OFF Otherwise 3 Fans Permanently On Fans active OFF Otherwise 4 Reduced SET Economy Permanently On Energy saving active Blinking Re...

Страница 14: ...16 17 LIGHT STANDBY UP DOWN ESC SET Enter Press and Hold Press and Hold Press and Release Press and Release Press and Release Press and Release Long press 5 sec Toggles light on and off If LED is on l...

Страница 15: ...ey pad will beep when unlocked and normal key pad operations performed Setting the Operating Set Point To change the operating set point press and release the set button to enter the machine menu set...

Страница 16: ...ss the set button to display the value and use the up or down button to change the value Once the value has been selected use the escape button to confirm the new value and return the pervious menu le...

Страница 17: ...User Manual for RIS Refrigerators Victory Rev 10 20 Victory 17...

Страница 18: ...P1 Att Afd HA1 PAO dAO OAO tA1 AH2 HIGH temperature 2 alarm ON Active Automatic SP2 Att Afd HA2 PAO dAO OAO tA2 AL2 LOW temperature 2 alarm ON Active Automatic SP2 Att Afd HA2 PAO dAO OAO tA2 EA Exter...

Страница 19: ...Rinse with clean water 3 Dry with a soft cloth 4 Polish with a soft cloth wiping with the grain 5 Wipe weekly with stainless steel cleaner Weekly Interior Cleaning 1 Remove all food food related item...

Страница 20: ...ip and secure into the notch in the front right corner of the raised panel 5 Examine condenser surface if dusty brush and vacuum the dust and lint from the surface of the coil Brush up and down to avo...

Страница 21: ...amount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Discolora...

Страница 22: ...ontrol No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage correct as needed Check start relay and start capacitor See next step No cooli...

Страница 23: ...ng MUST be in an area free from flame or spark It must be near an opened window or door A sign noting service of a system containing propane must be attached to the unit during refrigeration service A...

Страница 24: ...OT ALL MODELS 115VAC 60 HZ EVAP FAN BLU FAN RELAY 4 5 WHT CONTROL CIRCUIT 1 3 COMP RELAY 10 11 BRN WHT WHT BLK BLK WHT FASCIA HEATERS RED LIGHT RELAY 13 14 RED CABINET LIGHTS POWER SUPPLY BLACK WHITE...

Страница 25: ...in the Owner s Manual adjustment of door mechanisms or freight damage are not covered by this warranty For the purpose of this warranty the original purchaser shall be deemed to mean the individual or...

Страница 26: ...N LIEU OF ALL OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE HEREBY DISCLAIMED AND ALL OTHER OBLIGATIO...

Страница 27: ...___________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name _______________________________________________...

Отзывы: