User Manual for RIS Refrigerators
Victory
Rev. 10/20
Victory
18
Code Description Description
LED
Relay
Reset
Parameters involved to Enable alarm
E1
Probe Pb1 failure
ON
Active
Automatic
Ont, Oft
E2
Probe Pb2 failure
ON
Active
Automatic
Ont, Oft
E3
Probe Pb3 failure
ON
Active
Automatic
Ont, Oft
E4
Probe Pb4 failure
ON
Active
Automatic
Ont, Oft
E5
Probe Pb5 failure
ON
Active
Automatic
Ont, Oft
EL
LINK2 probe
failure
ON
Active
Automatic
Ont, Oft
Ei
Virtual probe
failure
ON
Active
Automatic
Ont, Oft
AH1
HIGH temperature
1 alarm
ON
Active
Automatic
SP1, Att,Afd,HA1,PAO,dAO,OAO,tA1
AL1
LOW temperature
1 alarm
ON
Active
Automatic
SP1, Att,Afd,HA1,PAO,dAO,OAO,tA1
AH2
HIGH temperature
2 alarm
ON
Active
Automatic
SP2, Att,Afd,HA2,PAO,dAO,OAO,tA2
AL2
LOW temperature
2 alarm
ON
Active
Automatic
SP2, Att,Afd,HA2,PAO,dAO,OAO,tA2
EA
External alarm
ON
Active
Automatic
PEA, EAL
OPd
Door open alarm
ON
not active
Automatic
PEA, tdO
Ad2
End of defrost due
to time-out
ON
not active
Automatic
dE1, dE2, dAt
Prr
Preheating alarm
ON
not active
Automatic
E10
Clock alarm
ON
not active
Automatic
HiP
HIGH voltage
alarm
ON
not active
Automatic
SPH, SPL, dFL, SoU
LoP
LOW voltage
alarm
ON
not active
Automatic
SPH, SPL, dFL, SoU
nPA
General pressure
switch alarm
ON
not active
Automatic
PEn, PEi
LPA
High pressure
switch alarm
ON
not active
Automatic
PEn, PEi
HPA
Low pressure
switch alarm
ON
not active
Automatic
PEn, PEi
PA
General pressure
switch alarm
ON
not active
Manual
PEn, PEi