38
VE272SFS Roll Grooving Tool
Pipe/tubing flare is
excessive.
Pipe/tubing support adjusted
too high for long pipe/tubing.
Refer to the "Long Pipe/Tubing Lengths"
section on page 13.
Tool is tilted forward (out of
level) while grooving long pipe/
tubing.
Refer to the "Tool Setup" section on page 7.
Incorrect pipe/tubing support
positioning of long pipe/tubing.
Pipe/tubing is “over-tracking”.
Move the pipe support to the right. Refer to
the "Long Pipe/Tubing Lengths" section on
page 13.
Pipe stabilizer is adjusted too
far inward.
Back off the pipe stabilizer to the furthest
point where it still stabilizes the pipe
effectively.
Larger diameter pipe
sways or vibrates
from side to side.
Incorrect pipe stabilizer
adjustment.
Move the pipe stabilizer in or out until the
pipe rotates smoothly.
Optional pipe stabilizer was not
purchased, installed, or used.
Purchase, install, or use the optional pipe
stabilizer.
The tool will not
groove the pipe/
tubing.
Hand pump valve is not closed
tightly.
Tighten the hand pump valve by turning the
knob clockwise.
Hand pump is low on oil.
Refer to the "Maintenance" section on
page 32.
Air is present in the hydraulic
system.
Refer to the "Maintenance" section on
page 32.
Pipe/tubing is beyond the wall
thickness capacity of the tool.
Refer to the "Tool Rating and Roll Selection"
section, starting on page 39.
Pipe/tubing grooves
do not meet Victaulic
specifications.
Groove diameter stop is not
adjusted correctly.
Refer to the "Groove Diameter Stop
Adjustment" section on page 18.
Pipe/tubing is beyond the wall
thickness capacity of the tool.
Refer to the "Tool Rating and Roll Selection"
section, starting on page 39.
The “A” Gasket Seat
or “B” Groove Width
dimensions do not
meet Victaulic
specifications.
Upper roll bearing is not
lubricated adequately.
Refer to the "Maintenance" section, starting
on page 32.
Incorrect upper roll, lower roll,
or both installed on the tool.
Install the correct rolls. Refer to the "Tool
Rating and Roll Selection" section, starting
on page 39.
Problem
Possible Cause
Solution
TM-VE272SFS 3776 Rev_B.fm Page 38 Friday, December 3, 2004 12:10 PM
Содержание VE272SFS
Страница 2: ......