VE272SFS Roll Grooving Tool
9
14.
Using a wrench, tighten the two hex
head bolts on the two legs to maintain the
level position.
15.
Attach the hand pump/pump support to
the left side of the tool with the two hex bolts
(supplied). Tighten the two hex bolts with a
wrench.
16.
Connect the hydraulic line from the hand
pump to the power cylinder with the connec-
tors provided.
17.
Hang the guard setting pad on the hook
provided under the base of the hand pump.
18.
Make sure the switch on the power drive
is in the “OFF” position. Plug the power drive
into an internally grounded electrical outlet.
The outlet must meet the requirements for the
power drive (refer to the power drive manu-
facturer’s instructions). If an extension cord is
used, refer to the "Extension Cord Require-
ments" section on page 5 for requirements.
19.
Turn the power drive switch to the posi-
tion that will produce
CLOCKWISE
rotation of
the chuck when viewed from the front of the
tool. On the Victaulic VPD752 or Ridgid 300
Power Drive, placing the switch in the
RE-
VERSE
position will produce clockwise rota-
tion of the chuck, lower roll, and pipe/tubing.
DANGER
• To reduce the risk of electric
shock, check the electrical
source for proper grounding and
follow all instructions.
• Before performing any mainte-
nance on the tool, turn the
switch on the power drive to the
“OFF” position, or disconnect
the power cord from the electri-
cal source.
Failure to follow these instructions could result in
death or serious personal injury.
WARNING
• The power drive MUST be operated with a safety
foot switch. If the power drive does not contain a
safety foot switch, contact the power drive manufac-
turer.
Operating the tool without a safety foot switch could
result in serious personal injury.
TM-VE272SFS 3776 Rev_B.fm Page 9 Friday, December 3, 2004 12:10 PM
Содержание VE272SFS