LOAD RATINGS

Series VAP131 components support pipe sizes 
1–24 inches/25.4–610 mm (11/2-foot/ 
0.5-meter to full, single 20-foot/6-meter random 
lengths).
The load rating for VAP131R Hydraulic, 
Adjustable Pipe Stands is 2000 pounds/ 
907 kilograms.
The load rating for VAP131F Hydraulic 
Positioners is 1200 pounds/544 kilograms 
with the wheels installed. The load rating for 
VAP131F Hydraulic Positioners is 
2000 pounds/907 kilograms without the wheels 
installed.
The load rating for VAP131T Assembly Tables is 
8000 pounds/3629 kilograms.
Ball transfers have a 700-pound/318 kilogram 
load rating. Make sure an adequate number 
of ball transfers are used to support the entire 
length of pipe.

 WARNING

•  DO NOT exceed the load rating of Series 

VAP131 components.

Failure to follow this instruction could result 
in serious personal injury, property damage, 
and product damage.

ELECTRICAL INFORMATION

The VAP131R and VAP131F are available  
in 120 VAC/12 amp and 220-volt/6-amp,  
single-phase power.

EXTENSION CORD REQUIREMENTS

When pre-wired outlets are not available and 
an extension cord must be used, it is important 
to use the proper cord size (i.e. Conductor Size 
American Wire Gauge). Cord size selection is 
based upon product rating (amps) and cord 
length (feet). Use of a cord size (gauge) thinner 
than required will cause significant voltage drop 
at the VAP131R or VAP131F during operation. 
Voltage drops may cause damage to the 
VAP131R or VAP131F, resulting in improper 
operation. 

NOTE:

 It is acceptable to use a cord 

size that is thicker than required.
The required cord sizes for cord lengths up to 
and including 100 ft/31 m are listed in the table 
below. Use of extension cords longer than 100 
ft/31 m must be avoided.

Drive Motor

Rating

volts/ 

amps

Cord Lengths 

feet/meters

25 

8

50

15

100

31

110

12 gauge

12 gauge

10 gauge

12

220

14 gauge

12 gauge

10 gauge

6

TM-VAP131_9

REV_D

TM-VAP131 

/ Operating and Maintenance Instructions Manual

Содержание TM-VAP131

Страница 1: ...lasses hardhat foot protection and hearing protection while working around pipe preparation tools Save this operating and maintenance manual in a place accessible to all operators of the tool If you n...

Страница 2: ...tile Procedure 17 Maintenance 17 Hydraulic Fluid Requirements 17 Parts Ordering Information 17 Troubleshooting 18 Pipe Ratings 19 HAZARD IDENTIFICATION Definitions for identifying the various hazard l...

Страница 3: ...e parts for any obstructions Make sure all components are installed and secured properly 4 Wear proper apparel Do not wear loose clothing jewelry or anything that can become entangled in moving parts...

Страница 4: ...pe Sizes Track Casters Rotating Table 1 1 Failure to follow instructions and warnings could result in serious personal injury property damage and or product damage Before operating or servicing any pi...

Страница 5: ...o follow instructions and warnings could result in serious personal injury property damage and or product damage Before operating or servicing any pipe preparation tools or accessories read all instru...

Страница 6: ...umper Guards 1 Failure to follow instructions and warnings could result in serious personal injury property damage and or product damage Before operating or servicing any pipe preparation tools or acc...

Страница 7: ...ies for accommodating various pipe sizes Refer to the NOTE in the following column The turnstile design of the VAP131R allows pipe to be spun around for grooving of both ends without dismounting the p...

Страница 8: ...ge ELECTRICAL INFORMATION The VAP131R and VAP131F are available in 120 VAC 12 amp and 220 volt 6 amp single phase power EXTENSION CORD REQUIREMENTS When pre wired outlets are not available and an exte...

Страница 9: ...ation of the hydraulic lift HYDRAU LIC PUMP STAR T STOP NOMINA L PIPE SIZE TEST JOG GROOVE SET GUARD FOR 40 60 1016 0 1524 0 MM PIPE ADJUST TO 50 SEC TIME RANGE CONSULT THE OPERATOR S MANUAL 5845 Rev...

Страница 10: ...cket 12 Ball Transfers Ball Transfer Supports 1 TM VAP131 Operating and Maintenance Instructions Manual 1 Service Manual for the Hydraulic Lift CONTENTS OF VICTAULIC HYDRAULIC ADJUSTABLE PIPE STAND OP...

Страница 11: ...nd product damage ASSEMBLY OF THE VAP131F HYDRAULIC POSITIONER 13 Nut Lock Washer VAP131F Hydraulic Positioners are shipped with the wheels removed The wheels can be attached to permit ease of transfe...

Страница 12: ...d level surface for the tool and VAP131R 2a The roll grooving tool must be installed on the tool support that is provided with the Kit 1 and Kit 2 Options Refer to the drawing above and below for inst...

Страница 13: ...ection 4a Position the VAP131R Hydraulic Adjustable Pipe Stand in an approximate operating location as follows Always refer to the Grooving Long Pipe Lengths section in the Operating and Maintenance I...

Страница 14: ...tion Pipe sizes listed on the bottom correspond with the lower ball transfer location Make sure the ball transfer is installed in the appropriate location on each ball transfer support Pipe Size Slots...

Страница 15: ...to roll groove the pipe Examine the roll grooved pipe end for A excessive flare and or B a scuffed pipe end face A If pipe is excessively flared it may be due to the VAP131R adjustments To minimize f...

Страница 16: ...e opposite end for grooving When rotating pipe walk with the pipe to maintain proper pipe balance MAINTENANCE This section provides information about maintaining Series VAP131 components in proper ope...

Страница 17: ...l grooving tool Insufficient pipe tracking angle Pipe rotating in the wrong direction Pipe not square cut Back end of pipe is above level Roll grooving tool is tilted forward Ball transfer s are jamme...

Страница 18: ...8 000 0 109 0 375 0 250 0 322 0 109 0 322 203 2 2 8 9 5 6 4 8 2 2 8 8 2 8 8 625 0 109 0 375 0 250 0 322 0 109 0 322 0 322 0 500 219 1 2 8 9 5 6 4 8 2 2 8 8 2 8 2 12 7 10 10 750 0 134 0 375 0 250 0 36...

Страница 19: ...ED ENTITIES IN THE UNITED STATES AND OR OTHER COUNTRIES 2015 VICTAULIC COMPANY ALL RIGHTS RESERVED TM VAP131 OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL Series VAP131 Victaulic Lean Fabrication Cell...

Отзывы: