Victaulic TM-VAP131 Скачать руководство пользователя страница 7

INTRODUCTION

NOTICE

•  Drawings and/or pictures in this manual 

may be exaggerated for clarity.

•  Series VAP131 components, along 

with this operating and maintenance 
instructions manual, contain trademarks, 
copyrights, and/or patented features that 
are the exclusive property of Victaulic 
Company.

•  For the VAP131R and VAP131F, always 

refer to the hydraulic lift manufacturer’s 
service manual, provided with the 
shipment, for complete operating and 
maintenance instructions.

 CAUTION

•  Series VAP131 components must be used 

ONLY for supporting pipe designated in 
the “Pipe Ratings” section.

•  Series VAP131 components are not 

designed to support fittings for roll 
grooving.

•  DO NOT use VAP131 components 

outdoors.

Failure to follow these instructions could 
result in damage to the equipment.

VAP131R Hydraulic, Adjustable Pipe Stands 
are designed specifically for supporting pipe to 
be grooved with Victaulic Roll Grooving Tools. 
The VAP131R is a heavy-duty unit that permits 
ease of pipe rotation on ball transfers, which are 
mounted to permit the use of pipe slings. A slot 
system is incorporated into the rotating table 
of the VAP131R, which permits adaptation of 
the ball transfer assemblies for accommodating 
various pipe sizes. Refer to the “NOTE” in the 
following column. 

The turnstile design of the VAP131R allows 
pipe to be spun around for grooving of both 
ends without dismounting the pipe. Casters are 
included with the VAP131R that are designed 
to engage with a special track system for ease 
of positioning the pipe onto the grooving tool’s 
lower roll.
VAP131F Hydraulic Positioners are heavy-duty 
units used in conjunction with the VAP131T to 
support grooved pipe, valves, and fittings during 
assembly. The VAP131F contains wheels that 
permit ease of transfer from one location to 
another.
The VAP131T Assembly Table is a heavy-duty, 
free-standing unit used in conjunction with the 
VAP131F for supporting grooved pipe, valves, 
and fittings during assembly. A slot system is 
incorporated into the VAP131T, which permits 
adaptation of the ball transfer assemblies for 
accommodating various pipe sizes. Refer to the 
“NOTE” below.

NOTE: For 1–3-inch/33.7–88.9-mm pipe 
sizes, friction slides and brakes (accessories 
sold separately) must be used in place of 
ball transfer assemblies on the VAP131R 
and VAP131T. All other pipe sizes are 
accommodated by using ball transfer 
assemblies. Refer to the graphics on page 12 
for proper placement of friction slides/brakes 
and ball transfer assemblies.

TM-VAP131_8

REV_D

TM-VAP131 

/ Operating and Maintenance Instructions Manual

Содержание TM-VAP131

Страница 1: ...lasses hardhat foot protection and hearing protection while working around pipe preparation tools Save this operating and maintenance manual in a place accessible to all operators of the tool If you n...

Страница 2: ...tile Procedure 17 Maintenance 17 Hydraulic Fluid Requirements 17 Parts Ordering Information 17 Troubleshooting 18 Pipe Ratings 19 HAZARD IDENTIFICATION Definitions for identifying the various hazard l...

Страница 3: ...e parts for any obstructions Make sure all components are installed and secured properly 4 Wear proper apparel Do not wear loose clothing jewelry or anything that can become entangled in moving parts...

Страница 4: ...pe Sizes Track Casters Rotating Table 1 1 Failure to follow instructions and warnings could result in serious personal injury property damage and or product damage Before operating or servicing any pi...

Страница 5: ...o follow instructions and warnings could result in serious personal injury property damage and or product damage Before operating or servicing any pipe preparation tools or accessories read all instru...

Страница 6: ...umper Guards 1 Failure to follow instructions and warnings could result in serious personal injury property damage and or product damage Before operating or servicing any pipe preparation tools or acc...

Страница 7: ...ies for accommodating various pipe sizes Refer to the NOTE in the following column The turnstile design of the VAP131R allows pipe to be spun around for grooving of both ends without dismounting the p...

Страница 8: ...ge ELECTRICAL INFORMATION The VAP131R and VAP131F are available in 120 VAC 12 amp and 220 volt 6 amp single phase power EXTENSION CORD REQUIREMENTS When pre wired outlets are not available and an exte...

Страница 9: ...ation of the hydraulic lift HYDRAU LIC PUMP STAR T STOP NOMINA L PIPE SIZE TEST JOG GROOVE SET GUARD FOR 40 60 1016 0 1524 0 MM PIPE ADJUST TO 50 SEC TIME RANGE CONSULT THE OPERATOR S MANUAL 5845 Rev...

Страница 10: ...cket 12 Ball Transfers Ball Transfer Supports 1 TM VAP131 Operating and Maintenance Instructions Manual 1 Service Manual for the Hydraulic Lift CONTENTS OF VICTAULIC HYDRAULIC ADJUSTABLE PIPE STAND OP...

Страница 11: ...nd product damage ASSEMBLY OF THE VAP131F HYDRAULIC POSITIONER 13 Nut Lock Washer VAP131F Hydraulic Positioners are shipped with the wheels removed The wheels can be attached to permit ease of transfe...

Страница 12: ...d level surface for the tool and VAP131R 2a The roll grooving tool must be installed on the tool support that is provided with the Kit 1 and Kit 2 Options Refer to the drawing above and below for inst...

Страница 13: ...ection 4a Position the VAP131R Hydraulic Adjustable Pipe Stand in an approximate operating location as follows Always refer to the Grooving Long Pipe Lengths section in the Operating and Maintenance I...

Страница 14: ...tion Pipe sizes listed on the bottom correspond with the lower ball transfer location Make sure the ball transfer is installed in the appropriate location on each ball transfer support Pipe Size Slots...

Страница 15: ...to roll groove the pipe Examine the roll grooved pipe end for A excessive flare and or B a scuffed pipe end face A If pipe is excessively flared it may be due to the VAP131R adjustments To minimize f...

Страница 16: ...e opposite end for grooving When rotating pipe walk with the pipe to maintain proper pipe balance MAINTENANCE This section provides information about maintaining Series VAP131 components in proper ope...

Страница 17: ...l grooving tool Insufficient pipe tracking angle Pipe rotating in the wrong direction Pipe not square cut Back end of pipe is above level Roll grooving tool is tilted forward Ball transfer s are jamme...

Страница 18: ...8 000 0 109 0 375 0 250 0 322 0 109 0 322 203 2 2 8 9 5 6 4 8 2 2 8 8 2 8 8 625 0 109 0 375 0 250 0 322 0 109 0 322 0 322 0 500 219 1 2 8 9 5 6 4 8 2 2 8 8 2 8 2 12 7 10 10 750 0 134 0 375 0 250 0 36...

Страница 19: ...ED ENTITIES IN THE UNITED STATES AND OR OTHER COUNTRIES 2015 VICTAULIC COMPANY ALL RIGHTS RESERVED TM VAP131 OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL Series VAP131 Victaulic Lean Fabrication Cell...

Отзывы: